![Hydronix Hydro-Control VI Operator'S Manual Download Page 46](http://html.mh-extra.com/html/hydronix/hydro-control-vi/hydro-control-vi_operators-manual_2192336046.webp)
46 Hydro-Control VI Operators Guide HD0456 Rev 1.7.1
2.9
Optimising CALC Mode
CALC Mode works by taking one average value at the end of the Dry Mix, and a second average
value at the end of the Wet Mix. Using these two values and the percentage moisture change
between the two points (this is the quantity of water added divided by the batch weight) it is
possible to calculate the quantity of water that is needed to get from any other start point to the
target moisture value.
Moisture
Time
Mixer
Loading
Dry Mix Time
Main Water
Addition
Wet Mix
Time
Discharge
Moisture
Water
Added
A
B
A
B
C
‘xx’ litres
‘x’ litres
‘y’ unscaled
units
Figure 19: The CALC Mode Calculation
As the diagrams in Figure 19 show, if it takes ‘x’ litres to get from moisture point A to moisture
point B then, as the sensor unscaled value is linear with moisture, a calibration line can be
obtained that can then be used to calculate the amount of water needed to get from any new
moisture point to the target value, B. In the diagram example it takes ‘xx’ litres to get from point
C to the target.
The real moisture percentage values are not required for this calculation as it relies only on the
change in the unscaled values. In order to achieve an accurate calibration the following values
must be known:
•
Batch weight
•
Quantity of water added
•
An accurate Dry Mix sensor reading
•
An accurate Wet Mix sensor reading (which also gives the target value)
Summary of Contents for Hydro-Control VI
Page 4: ...4 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 6: ...6 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 8: ...8 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 10: ...10 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 18: ...Navigation Chapter 2 18 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 20: ...Plant Operator Controls Chapter 3 20 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 34: ...Editing Recipes Chapter 6 34 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 40: ...Running the First Mix Chapter 7 40 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 56: ...Using Moisture Control Chapter 8 56 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 70: ...Setting Up User Accounts Chapter 11 70 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 72: ...Remote Support Chapter 12 72 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...
Page 86: ...Document Cross Reference Appendix C 86 Hydro Control VI Operators Guide HD0456 Rev 1 7 1 ...