HYDROMEA LUMA 100 Manual Download Page 6

LUMA 100

 

4/2021 

memory, click “Save”. To leave configuration mode and return to regular operation, click 
“Active mode”.  

3.2

 

Communication settings 

3.2.1

 

Serial baud-rate 

This is the baud-rate setting for the communication to the modem over the attached cable. The 
baud-rate has to match the selected baud-rate of the host computer or connected device. 
Available baud-rates are:  

9600, 19200, 38400, 57600, 115200 bits per second  (default 115200 bps) 

When changing the baud-rate of the modem, the baud-rate of the host PC also has to be 
changed to the same value.  

Note that the changed baud-rate is not permanent until a “Save” command is sent, which is 
only possible if the new baud-rate settings work on the modem and the host PC.  

3.2.2

 

Maximum packet size 

The modem collects serial input data from the RS232/485 connection to combine it into a 
packet. This parameter specifies the maximum packet size. Packets can be smaller if there is no 
more input data after a specified time period. Large values reduce overhead, small values 
improve latency. The default value is 64, which is a good compromise. 

3.2.3

 

Data wait time 

This parameter specifies the maximum time in microseconds that the modem will wait for 
additional data before sending a packet before the maximum packet size is reached. Larger 
values reduce packet overhead but increase the maximum latency. Smaller values improve 
latency, but increase the packet overhead, which results in lower average throughput. The 
default value is 2000 microseconds. 

3.2.4

 

Forward error correction 

Forward error correction makes the communication link more robust and reliable, at the cost of 
maximum bandwidth. The following settings are available: 

 

None

: No forward error correction is applied. This enables the highest throughput. 

 

2x bit correction:

 A codec that uses 2x redundancy to detect and fix bit errors 

 

1.5x bit correction

: A codec that uses 1.5x redundancy to detect and fix bit errors 

 

Burst (+30) correction:

 A codec that can detect and fix burst errors. It adds 30 bytes to 

the packet size. Burst correction is supported for serial baud-rates of 9600 bps and 
19200 bps. Higher baud-rates can be used only if the average speed of data 
transmission is below 19200 bps. 

Summary of Contents for LUMA 100

Page 1: ...LUMA 100 a fast low power optical underwater communication system Manual Ver 1 2 4 2021 ...

Page 2: ...ettings 6 3 2 1 Serial baud rate 6 3 2 2 Maximum packet size 6 3 2 3 Data wait time 6 3 2 4 Forward error correction 6 3 2 5 Packet transmit mode 7 3 2 6 Beacon period 7 3 2 7 Auto off delay 7 3 3 Sleep mode configuration example 7 3 4 Firmware update 8 4 Maintenance 8 5 Electrical and Software Characteristics 9 6 Mechanical Characteristics 10 7 Errata 12 ...

Page 3: ...able supply voltage 12 V 36 V When properly aligned and within communication range the two modems now provide a half duplex serial communication link 2 2 Operation When in active mode the modem will broadcast all data received over the cable and send over the cable all data received from the optical receiver When in sleep mode the modem ignores all data coming in from the optical receiver and the ...

Page 4: ...turns to a safe level 3 Modem configuration The LUMA modems can be configured with the LumaConf software available here note LumaConf for the LUMA 250LP also works with LUMA 100 https files hydromea com luma LumaConf_250LP zip The LUMA modems can be configured with the LumaConf software LumaConf runs on Windows 7 Windows 8 and Windows 10 64 bit version Installation is not required simply extract l...

Page 5: ...ud rate The default setting is 115200 bps but it may be different if the modems have been configured to another baud rate Click on Config mode and the parameters should become active instead of greyed out if all settings and connections are correct The modem is now in configuration mode which allows you to change the modem settings Changed settings will be applied instantly but will revert to the ...

Page 6: ...erhead small values improve latency The default value is 64 which is a good compromise 3 2 3 Data wait time This parameter specifies the maximum time in microseconds that the modem will wait for additional data before sending a packet before the maximum packet size is reached Larger values reduce packet overhead but increase the maximum latency Smaller values improve latency but increase the packe...

Page 7: ... installed on a sensor change auto off delay to 30 seconds see 3 2 7 on the modem B that wakes up the other modem e g on an ROV change beacon period to 2 seconds see 3 2 6 After changing settings click Refresh to verify that the modem received the correct value Click Save to store the new value permanently in the modem s internal flash Then click Active mode to leave config mode and put the modem ...

Page 8: ...that under Firmware the entry LUMA100 RS232 is selected click write Flash wait until the progress bar reaches 100 If it doesn t go through click Write Flash again until it does complete click Start application You should now be able to connect to the modem again as described above Verify that the modem settings are still correct they should carry across firmware updates in general but bigger updat...

Page 9: ...ission power 1 banks with 3 LEDs Interface Software selectable RS232 RS485 Emission wavelength 475 nm Beam pattern 120 degree cone Connector pinout 1 Supply voltage Vs 2 GND 3 RS232 RX RS485 D 4 RS232 TX RS485 D 5 n c 6 n c Error correction Software selectable Forward error correction overhead 2 1 Forward error correction overhead 1 5 1 Burst error correction Auto sleep Software selectable 0 off 1...

Page 10: ...TATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT IN NO EVENT SHALL HYDROMEA BE LIABLE FOR ANY DIRECT INDIRECT ONSEQUENTIAL PUNITIVE SPECIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF PROFITS BUSINESS INTERRUPTION OR LOSS OF INFORMATION ARISING OUT OF THE U...

Page 11: ...4 2021 LUMA 100 11 ...

Page 12: ...12 LUMA 100 4 2021 7 Errata Version Release date Errata 1 0 1 4 2021 Original version 1 1 22 12 2021 Updated logo Added Errata Updated links to LumaConf 1 2 7 4 2022 Updated link to LumaConf ...

Reviews: