1. System is located where it will not be subject to physical impacts or rough contact by heavy objects.
2. Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI.
3. Ensure the plas
ti
c retainer clip that holds the desalinator cartridge in place is fully engaged and locked in place. The slide
locks must snap into place in the slots. If the clip does not snap easily into place through the slots it means the cartridge is not
fully inserted into the connectors. Press top or bo
tt
om of cartridge to engage connectors un
ti
l it snaps into place properly.
4. All tubing connec
ti
ons, especially push-in quick connec
ti
ons, are fully inserted.
5. Tubing connected between the faucet and the drain saddle
fi
tti
ng (the
fi
tti
ng a
tt
ached to the sink drain pipe) runs "down-
hill" to the drain. There should be no loops or places where water would not
fl
ow out to the drain.
6. Feed water valve is open.
7. Within one to two hours a
ft
er ini
ti
al applica
ti
on of water pressure, check again for leaks especially at the tank, faucet tub-
ing and connectors. These parts will not see full pressure un
ti
l approximately 2 hours a
ft
er the system is ac
ti
vated.
8. Flush three tankfuls of product water to drain. If a chlorine scent persists, repeat
fl
ushing procedure.
Installa
ti
on Checklist