background image

1

MODEL OS-200

Wireless 

Outdoor Sensor

for

    Model  3200-

Plus

 

Model 3250-

Plus

 

Fuel Smart HydroStat Controls 

Model 4200 HydroStat-IC 

HydroStat Control

Installation Instructions 

and Operating Manual

• Low Transmitter battery status indicator 

on the Receiver

• Power and communication indicator lights
• Transmitter temperature range of -40°F 

to 140°F (-40°C to 60°C)

• Long battery life (minimum 10 years) 

with included 1.5V lithium AA batteries

• 5000 ft. (1500 m) open range
• 8 walls / 250 ft. (75 m) indoor range
• Transmits outdoor temperature every 10 

minutes

    

WARNING

   

Electrical shock hazard. 

To prevent electrical shock, death or equipment 

damage, disconnect power supply before installing or servicing control. 

Only qualified personnel may install or service this control in accordance with local codes and ordinances. Read 

instructions completely before proceeding.

    

CAUTION

     

   

To prevent serious burns, boiler should be thoroughly cooled before installing 

or servicing control.

    

WARNING

   

Frozen pipes/water damage. 

Central heating systems are prone to       

shut down as a result of power or fuel outages, safety related fault 

conditions or equipment failure. Installation of freeze protection monitoring or other precautions is recommended 

for unattended dwellings in climates subject to sustain below-freezing temperatures.

126 Bailey Road • North Haven, CT 06473 • (203) 776-0473 • FAX (203) 764-1711  
www.hydrolevel.com

The Hydrolevel Wireless 
Outdoor Sensor OS-200 
provides outdoor temperature 
measurement in any 
application without exterior 
wiring. The 

transmitter and 

receiver are sold pre-linked 
and are installation-ready. 
With exceptional range and 
a 10-year battery life, the 
Wireless Outdoor Sensor 
OS-200 provides maximum 
accuracy, convenience and 
reliability.

Wireless Outdoor Sensor 087

Receiver

Communication

Power

Low Battery

Link

TRANSMITTER

(OUTDOOR)

RECEIVER

Summary of Contents for OS-200

Page 1: ...s completely before proceeding CAUTION To prevent serious burns boiler should be thoroughly cooled before installing or servicing control WARNING Frozen pipes water damage Central heating systems are prone to shut down as a result of power or fuel outages safety related fault conditions or equipment failure Installation of freeze protection monitoring or other precautions is recommended for unatte...

Page 2: ...uillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Warning FCC and IC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment The antenna s used for this equipment must be installed to provide a separation dista...

Page 3: ...t appliances or other sources of electrical interference Easy access for wiring Approximately 5 feet 1 5 m off the finished floor Grasp the front cover by the fingertip grips on the top and bottom of the enclosure and pull the front cover off The enclosure is either mounted flush onto a wall or it can be placed onto a 2 x 4 non conductive electrical box The mounting holes in the enclosure accept 6...

Page 4: ...dd a transformer supplied by others as shown below The receiver unit must be powered with 24 VAC Batteries in the Transmitter unit Remove the cover from the transmitter unit Insert the included batteries as marked on the battery holder 1 5V lithium batteries are required to provide the specified battery life and temperature range Alkaline batteries have short life spans and may fail during cold we...

Page 5: ...evert to a power up condition a temperature of 75 F 24 C will be reported until the first transmission is received up to 10 minutes Communication Power Low Battery Link Wireless Outdoor Sensor 087 Receiver Communication Power Low Battery Link Wireless Outdoor Sensor 087 Receiver STEP 4 INSTALL TRANSMITTER The transmitter should be mounted on a northern exterior wall away from direct sunlight In or...

Page 6: ...tdoor Reset AND Warm Weather Shutdown Attach the spade connectors to the right and center spade posts OR and C for full outdoor reset functionality including warm weather shutdown protection Wiring this way overrides the Thermal Targeting function of the HydroStat control Warm Weather Shutdown Only WWSD Connect the wire ends to the left and center spade connectors WWSD and C to add warm weather sh...

Page 7: ...O O R D E S I G N T E M P E R A T U R E B O I L E R T E M P E R A T U R E STEP 6 SETTING THE HYDROSTAT CONTROL continued To set the desired warm weather shutdown temperature Press and hold the TEST SETTING BUTTON and simultaneously adjust the ECONOMY dial to the desired setting To turn the feature off which will allow space heating regardless of outdoor temperature press and hold the TEST SETTING ...

Page 8: ...ns that for each 1 degree increase in outdoor temperature the boiler temperature will decrease 2 degrees Conversely for each 1 degree drop in outdoor temperature the boiler temperature will increase 2 degrees The control adds 10 degrees to the calculated reset temperature and provides a 20 degree differential for burner operation So if the control calculates a reset temperature of 150 F it will se...

Page 9: ...hat the communication LED turns green The battery life of the transmitter batteries may have expired This is likely the issue if the batteries have been in extended service They can be replaced with 1 5V lithium batteries The link may have been interrupted Try re linking the devices as described on page 4 3 If the communication LED remains off for over 30 minutes please call Tech Support at 203 77...

Page 10: ...30307 13 F 25 C 97007 4 F 20 C 72910 5 F 15 C 55303 14 F 10 C 42316 23 F 5 C 32651 32 F 0 C 25395 41 F 5 C 19903 50 F 10 C 15714 59 F 15 C 12493 68 F 20 C 10000 77 F 25 C 8056 86 F 30 C 6530 95 F 35 C 5325 104 F 40 C 4367 113 F 45 C 3601 122 F 50 C 2985 131 F 55 C 2487 140 F 60 C 10K Type 2 NTC Thermistor ...

Page 11: ... 7 8 W x 7 8 D 120 x 74 x 23 mm Enclosure Transmitter White ABS plastic NEMA 4X Receiver White PVC plastic NEMA Type 1 Packaged Weight 0 92 lb 420g Sensor 10K Type 2 Approvals FCC and IC Operating range Transmitter 40 to 140 F 40 to 60 C Receiver Indoor use only 32 to 122 F 0 to 50 C RH 90 non condensing Receiver power 24 V ac 10 1 VA ...

Page 12: ...products which is made within such period we will at our option repair or replace such products or refund the purchase price paid to us by you for such products In no event shall Hydrolevel Company be liable for any other loss or damage whether direct indirect incidental or consequential This warranty is your EXCLUSIVE remedy and shall be IN PLACE OF any other warranty or guarantee express or impl...