INITIAL CONTROL SET
-
UP
MUST BE PERFORMED PRIOR TO LIFT OPERATION AND/OR ATTEMPTING TO LOAD A BOAT
:
The Harbor Hoist controller is sold in two configurations, with either an internal or ex-
ternal leveling sensor. This depends on the size of lift and dock configuration.
Each have an unique setup processes if you do not know which you have please contact
your installer or Harbor Hoist customer service support.
Internal Level Sensor Setup:
STEP 1: Determine the control position of the boat:
Starboard
or
Port
A: While facing the control if the front of the boat is to the right, it is
Starboard
.
B: While facing the control if the front of the boat is to the left, it is
Port
.
STEP 2: Program the control in relation to boat placement
A: For a
Starboard
control placement: press
STOP
and
UP
at the same time until the
Starboard
LED
lights.
For a
Port
control placement: press
STOP
and
DOWN
at the same time until the
Port
LED lights.
B: When the corresponding LED light (
starboard
/
port
) remains on, the control is set.
C:
PRECAUTIONARY NOTE:
If the valves actuate (open), press
STOP
and begin again.
STEP 3: Program the control level
A: Press the
UP
button; this will raise the lift to its highest point.
B: Each tank must be bubbling from the relief hole before hitting
STOP
.
If a tank does not bubble out hit
STOP
and zero the control.
-
To zero the control, push and hold the
UP
and
DOWN
buttons at the same time until the 5 valve
LED
’
s flash.
-
Press
UP
,
and allow additional time for all tanks to bubble from the relief holes; only then press
STOP
.
-
To zero the control, push and hold the
UP
and
DOWN
buttons at the same time until the 5 valve
LED
’
s flash.
C: Your lift is now set and ready to use.