FUNCTION

DIRECTIONS

ALARM

By default, the audible alarm for CO

2

 levels exceeding set level, is set to OFF. 

Once ALARM is selected (by pressing ENTER), use either UP or DOWN to 

toggle the selection from ON to OFF or vice versa. Press ENTER one more 

time to confirm. A regular bell icon will be displayed if alarm is on; a silenced 

bell icon will appear on the screen if the alarm is set to off.

TIME

This function allows the user to adjust the real time. Once TIME is selected, 

use UP and DOWN to adjust the current date and time. Press ENTER to 

confirm.

LOG

This feature allows the user to see historical data recorded in the log at any 

point that is displayable on the chart. First make sure the desired Zoom 

Level is selected before enabling this function. Once LOG is enabled, use 

UP and DOWN to toggle between the time divisions to see all parameters’ 

measurements for each division. Press ENTER once more to exit this mode.

CALI

Use this function to calibrate your device with outside atmospheric CO

2

 

levels (usually around 400 ppm). Select this mode, hold ENTER for 3 

seconds until a beep is heard, and the chart will read “Calibrating”. Then 

place the device outdoors for 20 minutes. To escape, press MENU. Make 

sure the device is far from a source of CO

2

, not in direct sunlight, and not 

exposed to water. Do not stand near the device during calibration mode.

ALTI

This feature provides an altitude correction to the CO

2

 level for increased 

accuracy. Select this feature, then use UP and DOWN to input the current 

altitude in meters. Press ENTER once altitude is correct.

ºC/ºF

Use this feature to toggle between Celsius and Fahrenheit for the 

temperature display. First use UP and DOWN, then ENTER when the 

desired one is selected.

ADV

This function toggles between three things when selected: 1. Changing the 

alarm and lights to suit levels for Low Border; 2. Changing the alarm and 

lights to suit levels for Hi Border; and 3. Restore Factory setting.
Restore Factory Setting will reset the device to factory settings and erase 

all stored data in the chart. To use any of these modes, hold ENTER for 3 

seconds until an audible beep is heard.

(Return)

Exits the main menu. No options will be displayed on the green bar. A 

different audible beep will be heard in this option.

MAIN MENU FUNCTIONS CHART

10

Summary of Contents for Autopilot APCEMDL

Page 1: ...APCEMDL USER MANUAL CO2 MONITOR w Memory Data Storage AutopilotControllers com...

Page 2: ...AutopilotControllers com 2...

Page 3: ...HAT S INTHE BOX 5 LCD DISPLAY 6 DISCLAIMERS 6 OPERATING INSTRUCTIONS 7 INITIAL SETUP 7 SD CARD FOR LOGGER 7 MAIN MENU FUNCTIONS 8 TREND CHART 9 TREND CHART ZOOM 9 MAX MIN 9 CLOCK 9 MAIN MENU FUNCTIONS...

Page 4: ...ddition it automatically records logged data to an included microSD card and comes equipped with a built in microSD card port The card is removable and easily exported to a computer into an Excel file...

Page 5: ...RTS LIST A Power cord B USB Power Adapter C 1GB Micro SD card D CO2 Monitor 2 0 50 8 mm A B D C Hole for Rope Strap strap not included Holes for Screws screws not included Calibration Hole for factory...

Page 6: ...d data on the chart This device is not intended for workplace hazard CO2 monitoring nor is it intended as a definitive monitor for human or animal health institutions life sustenance or in any medical...

Page 7: ...om the unit to the included microSD card It logs date time CO2 temperature and relative humidity RH data You can export and view the logged data by using an SD card reader The unit creates a csv file...

Page 8: ...brought up the green bar will remain blank leaving the UP DOWN buttons to toggle between parameters and zoom levels respectively Pressing MENU once will bring up the main menu with a flashing bar indi...

Page 9: ...the display there are two numerical indicators MAX and MIN As the zoom level is changed the MAX and MIN values will reflect the maximum and minimum values on the chart of the selected CO2 parameter At...

Page 10: ...mode hold ENTER for 3 seconds until a beep is heard and the chart will read Calibrating Then place the device outdoors for 20 minutes To escape press MENU Make sure the device is far from a source of...

Page 11: ...5 ppm 1000 2000 10 ppm 2000 Temp Dependence 0 1 of reading per C or 2 ppm per C whichever is greater referenced to 25 C Pressure Dependence 0 13 of reading per mmHg corrected by user s altitude input...

Page 12: ...ied warranty lasts or the exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the APCEMDL co...

Reviews: