background image

APCEMDL

USER MANUAL

CO

2

 MONITOR 

(w/Memory & Data Storage) 

AutopilotControllers.com

Summary of Contents for Autopilot APCEMDL

Page 1: ...APCEMDL USER MANUAL CO2 MONITOR w Memory Data Storage AutopilotControllers com...

Page 2: ...AutopilotControllers com 2...

Page 3: ...HAT S INTHE BOX 5 LCD DISPLAY 6 DISCLAIMERS 6 OPERATING INSTRUCTIONS 7 INITIAL SETUP 7 SD CARD FOR LOGGER 7 MAIN MENU FUNCTIONS 8 TREND CHART 9 TREND CHART ZOOM 9 MAX MIN 9 CLOCK 9 MAIN MENU FUNCTIONS...

Page 4: ...ddition it automatically records logged data to an included microSD card and comes equipped with a built in microSD card port The card is removable and easily exported to a computer into an Excel file...

Page 5: ...RTS LIST A Power cord B USB Power Adapter C 1GB Micro SD card D CO2 Monitor 2 0 50 8 mm A B D C Hole for Rope Strap strap not included Holes for Screws screws not included Calibration Hole for factory...

Page 6: ...d data on the chart This device is not intended for workplace hazard CO2 monitoring nor is it intended as a definitive monitor for human or animal health institutions life sustenance or in any medical...

Page 7: ...om the unit to the included microSD card It logs date time CO2 temperature and relative humidity RH data You can export and view the logged data by using an SD card reader The unit creates a csv file...

Page 8: ...brought up the green bar will remain blank leaving the UP DOWN buttons to toggle between parameters and zoom levels respectively Pressing MENU once will bring up the main menu with a flashing bar indi...

Page 9: ...the display there are two numerical indicators MAX and MIN As the zoom level is changed the MAX and MIN values will reflect the maximum and minimum values on the chart of the selected CO2 parameter At...

Page 10: ...mode hold ENTER for 3 seconds until a beep is heard and the chart will read Calibrating Then place the device outdoors for 20 minutes To escape press MENU Make sure the device is far from a source of...

Page 11: ...5 ppm 1000 2000 10 ppm 2000 Temp Dependence 0 1 of reading per C or 2 ppm per C whichever is greater referenced to 25 C Pressure Dependence 0 13 of reading per mmHg corrected by user s altitude input...

Page 12: ...ied warranty lasts or the exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you Hydrofarm will at our discretion repair or replace the APCEMDL co...