![Hydrofarm ACTIVE AIR ACAN12 Instructions Manual Download Page 11](http://html.mh-extra.com/html/hydrofarm/active-air-acan12/active-air-acan12_instructions-manual_2192056011.webp)
INSTRUCTIONS
11
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES
SUGGESTED REMEDIES
Unit does not turn on when pressing
ON/OFF button
P1 Error Code
The Water Collection Tray is full. Turn
off the unit, drain the water from
the Water Collection Tray and restart
the unit..
The air filter is blocked with dust or
animal hair
Reset the temperature
Unit does not cool well
The windows or doors in the room
are not closed.
Turn off the unit and clean the filter
according to instructions
Exhaust hose is not connected or is
blocked
Turn off the unit, disconnect the
hose, check for blockage and
reconnect the hose
The unit is low on refrigerant
Call a service technician to inspect
the unit and top off refrigerant
Temperature setting is too high.
Decrease the set temperature.
The windows and doors in the room
are open
Make sure all windows and doors
are closed
The room area is too large
Double-check the cooling area
There are heat sources inside the
room
Remove the heat sources if
possible
The unit is noisy and vibrates too
much
The ground is not level
Place the unit on a flat, level surface
The air filter is blocked with dust
or animal hair
Turn off the unit and clean the
filter according to instructions
The unit makes a gurgling sound
This sound is caused by the flow of
refrigerant inside the unit
This is normal.
accordance with national wiring regulations.
• Do not operate your air conditioner in a wet
room such as a bathroom or laundry room.
• Contact the authorized service technician for
repair or maintenance of this unit.
• Your air conditioner should be used in such a
way that it is protected from moisture. e.g.
condensation, splashed water, etc. Do not
place or store your air conditioner where it
can fall or be pulled into water or any other
liquid. Unplug immediately if any contact
with water occurs.
• Always transport your air conditioner in a
vertical position and set it on a stable, level
surface during use.
• Turn off the product when not in use.
• Always contact a qualified person to carry
out repairs.
• Keep an air space of at least 12
"
/30 cm all
around the unit away from walls, furniture
and curtains.
• If the air conditioner is knocked over during
use, turn off the unit and unplug from the
power supply immediately.
• Do not touch the unit with wet or damp
hands or when barefoot.
• Do not press the buttons on the control panel
with anything other than your fingers.
• Do not remove any fixed covers. Never use
this appliance if it is not working properly, or
if it has been dropped or damaged.
• Never use the plug to start and stop the unit.
Always use the switch on the control panel.
• Do not cover or obstruct the inlet or outlet
grilles.
• Do not use hazardous chemicals to clean
or come into contact with the unit. Do not
use the unit in the presence of flammable
substances or vapors such as alcohol,
insecticides, gasoline, etc.
• Do not use this product for functions other
than those described in this instruction
manual.
• Unit must remain upright at all times, even
during transportation and storage. If the unit
has been tipped on its side it must remain
upright for 24 hours before use. Failure to do
so can cause permanent damage.