A.

 

Set  the  “D”  (roof)  panel  on  the  “BS-A-BL”  assemblies  and  fasten  in  place  using  hex  headed  screws 
through any (all) holes provided at panel stud locations.   

5.

 

Using  one  (1)  hex  headed  screw  for  each,  attach  the  Outside  Corner  Anchoring  Brackets  to  the 
“BS-A-BL”  sections.  Using  one  (1)  anchor  for  each  bracket,  fasten  them  to  the  concrete  (Fig  1A).  
Fasten one (1) Outside Corner Anchoring Bracket at both corners on one side. 

A.

 

Attach the Inside Anchoring Brackets to the “B#” panels at the bottom, inside at the concrete (Fig 1B).  
Using  one  (1)  anchor  for  each,  fasten  each  bracket  to  the  concrete.    Fasten  the  Inside  Side  Anchoring 
Brackets to the “B#” panels and concrete along one side of the enclosure. 

B.

 

Insert the Inside Roof Clips into the “D” (roof) panel at the “B#” panel studs (Fig 1C).  Using one (1) 
hex headed screw for each, attach the clips to the “B#” panels as shown. 

C.

 

Repeat Steps 5, 5A and 5B on the other side of the enclosure. 

 
 

 

NOTE: model sizes and configurations vary, see the chart.  

6.

 

Using one (1) hex headed screw, attach an Outside Corner Anchoring Bracket to an “A-B#” (corner) 
assembly.  Using one (1) anchor per bracket, fasten it to the concrete (Fig 1A).  Fasten one (1) Outside 
Corner Anchoring Bracket at both “A-B#” (corner) assemblies on one side. 

A.

 

Attach  the  Inside  Anchoring  Brackets  to  the  “B#”  panel  studs  at  the  bottom,  inside  at  the  concrete 
(Fig 1B).  Using one (1) anchor  per  bracket,  fasten them to  the concrete.  Fasten the Inside Anchoring 
Brackets to the “B#” panel and concrete along one side of the enclosure. 

Summary of Contents for Safe-T-Cover 800 Series

Page 1: ...of the enclosure 3 wider than ID and 3 longer than ID 2 The PVC masking film will help to protect the finish of the metal panels during installation These coatings should be left intact and removed only after assembly of the enclosure is complete A Assemble the BS A BL side end side assemblies using hex headed screws For best results insert a bead of silicone caulk into the inside bend of the A pa...

Page 2: ...h fasten each bracket to the concrete Fasten the Inside Side Anchoring Brackets to the B panels and concrete along one side of the enclosure B Insert the Inside Roof Clips into the D roof panel at the B panel studs Fig 1C Using one 1 hex headed screw for each attach the clips to the B panels as shown C Repeat Steps 5 5A and 5B on the other side of the enclosure NOTE model sizes and configurations ...

Page 3: ...st stud Using one 1 hex headed screw attach the clip to the F post Fig 1C 8 Provide a ground fault interrupter device in all electrical circuits per all applicable codes Install the heater s as per manufacturer s instructions and governing local and national codes 9 For maximum protection it is suggested that the area between the bottom of the enclosure and the concrete base should be caulked exce...

Page 4: ...l No 800T Series CONTENTS 1 Your assembly should include A 2 A end Panels B 2 BS side Panels C 2 BL side Panels D 2 C access Panels E 1 Cw d access Panel F 1 D roof Panel G 1 F side Post H 4 Outside Corner Anchoring Brackets 1 x 1 I 5 Inside Anchoring Brackets 3 x 3 J 5 Inside Roof Clips K 1 Package of Anchors L 1 Package of Hex headed screws M 1 Masonry Bit N 1 Magnetic Chuck 2 Tools you will nee...

Reviews: