HydroCheck HC7000v2 Instructions Download Page 2

  
TROUBLESHOOTING: 

Alarm & LED Guide 

  

Smart Button Features 

WARRANTY: 

STAK Enterprises Inc. warrants the model

 HC7000v2 

to be free from defects in materials and workmanship for its normal, useful life, for a peri-

od of 5 years from the date of purchase. STAK Enterprises Inc. makes no other express warranty for this device. No agent, representative, deal-

er, or employee of STAK Enterprises Inc. has the authority to increase or alter the obligations or limitations of the warranty. The company's 

obligation of this warranty shall be limited to the repair or replacement of any part of the HC7000v2 which is found to be defective in materials or 

workmanship under normal use and service during the 5 year period of product use by original product owner commencing with the date of pur-

chase. Owner must pay all shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, 

nor shall it apply to products which, in the sole judgment of STAK Enterprises, Inc. have been subject to negligence, abuse, accident, tampering, 

alteration, misapplication, or improper installation. 

THE DURATION OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING THAT OF MERCHANTABILITY OR FITNESS FOR ANY PARTIC-

ULAR PURPOSES, SHALL BE LIMITED TO THE NORMAL, USEFUL LIFE OF THE PRODUCT, COMMENCING WITH THE DATE OF PUR-

CHASE.  IN NO CASE SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF 

THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER. 

Step 3

Release the 

Smart Button

 when the desired run time is reached. The 

output will turn off and the switch is now reprogrammed with the new 

Additional Run Time

NOTE: 

Loss of power does not affect programmed run time. 

Meaning

Possible Cause

Red LED

The switch's output is off (the pump is off).

None—Normal operation

Green LED

The pump is on and water is above the Lo-Sensor.

None—Normal operation

Flashing Green LED

The pump is on and operating in Timed Mode.

None—Normal operation

Fixed Rate Alarm

 

(Weak or Missing Ground)

Weak ground reference detected during a pump cycle.

See website for more information 

www.hydrocheckproducts.com

2-Beep Alarm 

(No Pump Current Detected)

The switch did not detect a motor current during a pump cycle.

• Pump is not plugged in 

• Pump failure

3-Beep Alarm 

(High Water Alarm)

High Water Alarm will sound if water does not drop below the Hi-

Sensor within 25 seconds following two anti-airlock cycles. 

NOTE:

 See the Product FAQ page on our website for more 

information about airlock cycles www.hydrocheckproducts.com

• Pump failure 

• Pump can’t keep up 

• Blocked or frozen discharge pipe 

• Trapped air is preventing normal pump 

operation (airlock)

Goal

Method

Mute Alarm

Pressing and releasing the Smart Button while an alarm is active will silence the alarm for 24hrs.

Disable Alarm

Pressing and holding the Smart Button while an alarm is active will disable the alarm until the switch is reset. The 
Smart Button should be pressed and held until the device sounds a short beep indicating that the alarm was suc-
cessfully disabled. 

Switch Reset

Press and hold Smart Button while plugging switch into a 120 VAC outlet. A short beep will sound to indicate that 
the switch has been reset. Resetting the switch returns all settings back to the original factory defaults.

Cancel Cycle

Press and release the Smart Button while the pump is on to cancel the cycle.

 

 

www.hydrocheckproducts.com | [email protected] | 1(877)-225-2124

2

Rev-A