background image

HC5000T Sewage Pump Switch

   

with Programmable Cycle Length and Built-in Alarms

 

Overview: 

The HydroCheck 

HC5000T Electronic Sewage Pump Switch with Programmable Cycle Length and Built-in Alarms

 is compatible with all 

sewage/ejector pumps and is designed to replace traditional float switches. Use the Smart Button to easily program a precise cycle length for 
your sewage pump that will begin when liquid reaches the sensor tip. See 

Troubleshooting

 section for Smart Button, LED and Alarm specifica-

tions. Not rated for outdoor use. 

READ PRIOR TO INSTALLATION: 

1.

The 

“piggyback plug”

 attached to the mechanical float switch 

cannot be used with the HC5000T

It must be disconnected and 

remain disconnected. 

2.

If your sewage pump has 

internal float switch wiring

, i.e. does not have a “piggyback plug”, then you 

must

 secure the float in an 

upward position

 as if the pit were full. This assures that the internal switch is always closed and that the pump is always enabled. 

Step-by-Step Installation

 

Run Time Adjustment  

Step 1

For an ideal installation, drill a 9/16” hole through the sewage pit 

cover. Insert the 

sensor

 (A) through the provided 

rubber grom-

met 

(B). 

Step 2

Lower the 

sensor

 (A) into the pit so that the tip of the sensor is 

approximately 1" below the inlet pipe to the pit.  

NOTE: 

Make sure the sensor is hanging freely and is not in con-

tact with anything else in the pit, such as the pump's power cord, 
the wall of the pit, etc. 

Step 3

Using the provided 

tie wrap 

(C), secure the sensor cable to a por-

tion of the 

discharge pipe

 (D) that is located outside of the pit so 

that the sensor does not drop lower in the pit. 

Step 4

Securely plug the drilled hole with the 

rubber grommet

 (B). 

NOTE:

 Only applicable if a hole was drilled in Step 1.

Step 5

Plug the 

control module

 (E) into a 3-prong 120 VAC outlet.

Step 6

Plug the 

pump's power cord

 (F) into the front of the 

control 

module

 (E). 

Step 7

Adjust the run time by following the 

Run Time Adjustment 

steps 

in the table below. 

NOTE:

 This product defaults to a 10 second run time and can be 

reprogrammed at anytime. Achieving the optimal pump cycle 

length may take several attempts.

Step 8

TEST YOUR INSTALLATION BEFORE LEAVING IT FOR UNAT-
TENDED USE. 

NOTE: 

This product 

will not work if tested in a cup of water. 

See 

How the Sensor Works: Why won’t my pump turn on? 

below.

Step 1

Silence or eliminate all active alarms: There should be no audible alarms active (See 

“Smart Button Features”

 on how to disable 

alarm). 

Step 2

Press and hold the 

Smart

 

Button

 for approximately 5 seconds, or until the output turns on and the LED starts to flash green. The 

output turning on marks the start of the desired run time. 

NOTE:

 If the pump is in the middle of a cycle, first cancel the cycle by pressing and releasing the Smart Button.

Step 3

Release the 

Smart

 

Button

 when the desired run time is reached. The output will turn off and the switch is now reprogrammed with 

the new run time. 

NOTE: 

Loss of power does not affect the programmed run time. 

www.hydrocheckproducts.com | [email protected] | 1(877)-225-2124

A. Sensor

D. Discharge Pipe

B. Rubber Grommet

E. Control Module

C. Tie Wrap

F. Pump Power Cord

*Inlet pipe and 120 VAC outlet are

 

not pictured.

Product Specifications

Product Dimensions

2.8 x 2.5 x 3.5 in

Weight

14.4 oz

Output Rating

120 VAC, 15 Amp, 1 HP

Alarm Rating

80 dB

Power

120 VAC, 60 Hz

Sensor Cable Length

12 ft

Rev-A

1

Installation Key