1.
Temporarily remove the Media Removal Tool from the Quadmaxx® Backing.
2.
Use a level and pencil to locate your 4 wall mount locations. If using wall anchors, press the tip of the
anchors into drywall using a #2 Phillips Screwdriver. Drive anchor clockwise until anchor stops flush
with wall. Do not over tighten anchors. Place Backing over marked locations or inserted anchors and
insert wall mount screws. Tighten screws flush with the Backing. If using anchors, a “pop” sound
indicates correct installation.
Your system may require the insertion of the media. Open the tube and check. Follow the instructions
and then continue with attaching the filter tubes.
Unpack the new HydroCare Purification Media. One Media package is provided for each sleeve( Fig 5).
Using your fingers, insert the first pad, the gold colored piece into the outlet side of the Sleeve which
is the side with the arrow pointing away (See Figure 6). Using your fingers, put your (8) black colored
pieces into the sleeve one at a time pushing the pieces into the Sleeve as you go. Place the thick
micron pad next to the last black piece. The thin pad goes in last.
3.
Thread the Outlet End Cap back into place. Repeat for each Sleeve from step 5.
4.
Use remaining Silicone Grease to coat the outsides of the copper inlets and outlets.
5.
Make sure each Sleeve is squared up. Put each Sleeve on a flat service and look to see that the elbows line up
with each other (See Figure 7). Adjust the elbows by tightening or loosening each End Cap.
6.
Firmly press your Sleeves back onto your Quadmaxx Pipe Manifolds.
7
Slowly turn your main water feed on until water returns to your open faucet and check for leaks.
NOTE:
The media contains carbon fines (very fine black powder). After installation, flush the new media for 5 minutes
before using the water.
Figure 5
Figure 6
Figure 7
7.
Rotate Pipe Manifolds so the inlets and outlets are facing you and sit perpendicular with the Backing.
You can use the open end of the Media Removal Tool to make slight adjustments to the Manifolds
(See Figure 1).
8.
Store your set of Sleeve Bypass Caps in the two holes provided.
9.
Use your fingers to coat the outsides of the copper Manifolds with the Silicone Grease
provided (See Figure 2).