HydroCare O2 Hydro Well System Installation, Use & Care Manual Download Page 2

- 2 - 

O2 Hydro SM 
20170222 

 

 

Assembly Instructions 

 

1.) You have received a Vortech Tank that is built with the distributor tube installed.  Leave the Distributer Tube Cap on 

and put the Funnel in place

 (See Figure 1)

 

Pour in the Media Package.  

 

2.) Remove funnel, wipe the mouth of the Media Tank, and remove the Distributer Tube Cap.  Coat the outside of the 

Media Tank Distributer Tube with silicon from top edge and down 1”.  

 

3.) IMPORTANT 

- Install Strainer Basket (Part #10) to the underside of the Main Control Head. Be certain to twist 

on clockwise and tighten until securely locked in place.  

 

4.) Coat the inlet, outlet, and tank O-rings on the Main Control Head with Silicone. You do not need to remove these O-

rings when applying the Silicone.   

 

5.) Using a ¼” Nut Driver, loosen screws on retainer clips on Main Control Head. Attach the Bypass assy. to the Main 

Control Head and tighten back into place 

(See Figure 2)

.  Line up Main Control Head with the Distributer Tube and push 

down on the control head until snuggly in place. Thread control head on to the tank until tight.   

Important: Make certain that the air intake assembly at the right side of the Control Valve is vertical in the 

upright position with the air screen at the top.

  

 

       

         

    

                  

       

 

         

 Figure 1                                   Figure 2   

              Figure 3  

                                Figure 4 

 

 
 

6.) Connect the drain line to the drain fitting using clamp provided and a 3/8” Nut Driver 

(See Figure 3)

.  Run other end 

of drain line into your drain. 

 

    

                              

 

 
 

 

          

 
 
 
 
 