Troubleshooting Chart:

* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit which are

exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove
an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively,
a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit
with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by
drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.

1. No discharge

a. No water

a. Open water supply

b. Magnetic valve not functioning

b. Install valve parts kit

c. Excessive water pressure

c. Install regulator if water pressure exceeds

4.14 bar (flowing)

d. Eductor clogged

d. Clean* or replace

2. No concentrate draw

a. Clogged foot valve

a. Clean or replace

b. Metering tip or eductor has

b. Clean (descale)* or replace

scale build-up

c. Low water pressure

c. Minimum 1.76 bar (with water running)

required to operate unit properly

d. Discharge tube(s) not in place

d. Push tube firmly onto eductor discharge

or flooding ring missing from

hose barb; ensure inner discharge tube

inner discharge tube

is installed and has flooding ring.

e. Concentrate container empty

e. Replace with full container

f. Inlet hose barb not screwed

f. Tighten, but do not overtighten

into eductor tightly

g. Clogged water inlet strainer

g. Disconnect inlet water line and clean

strainer

3. Excess concentrate draw

a. Metering tip not in place

a. Press correct tip firmly into barb on

eductor

b. Chemical above eductor

b. Place concentrate below the eductor

4. Failure of unit to turn off

a. Water valve parts dirty or

a. Clean* or replace with valve parts kit

defective

b. Magnet doesn't fully return

b. Make sure magnet moves freely.

c. Push button stuck

c. Remove button and clean cabinet/button

to remove any dirt lodged in slide recess

5. Excess foaming in discharge

a. Air leak in pick-up tube

a. Put clamp on tube or replace tube if brittle

b. Inner discharge tube not in place

b. Install inner discharge tube

6. Water discharge from air

a. Restricted discharge hose

a. Ensure discharge tube is not immersed,

vents on eductor

kinked or elevated. Ensure there is no
liquid in the discharge tube when begin-
ning to operate dispenser

b. High water pressure

b. Install pressure regulator if

 flowing water

pressure

 exceeds 4.14 bar

Solution

Cause

Problem

10091787

Hydro Systems Europe Ltd, 

Unit 3 The Sterling Centre, Eastern Road, Bracknell, Berks. England RG12 2PW

 Tel.: +44 (0)1344 488880  Fax: +44 (0)1344 488879 www.hydrosystemseurope.com

Summary of Contents for AccuDose 3833HFA-2

Page 1: ...of discharge tube over eductor discharge outlet and IDT Hook may be installed to allow discharge tube to hang from dispenser when not in use 8 Replace cabinet cover Push the sides in behind the latch holes to snap the cover in place The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover 9 Connect water supply hose of at least 13mm ID to water in...

Page 2: ...achieved can only be ascertained by using the Measurement of Concentration Procedure The clear undrilled tip is provided to permit drilling to size not listed shouldyouneedadilutionratiothatfallsbetweenstandard tip sizes Measurement of Concentration You can determine the dispensed water to product ratio for any metering tip size and product viscosity All that is required is to operate the primed d...

Page 3: ...10075980 Valve parts kit a diaphragm b armature c spring d valve bonnet 10 10079010 Spring 11 10079000 Magnet 12 a 160GB 4 LPM Eductor assembly b 161GB 14 LPM Eductor assembly c 440101 Suction stub only 13 a 10070170 4 LPM inner discharge tube b 10070470 14 LPM inner discharge tube 14 a 10064794 4 LPM outer discharge tube 18cm b 10077315 14 LPM outer discharge tube 1 2 m 15 10080720 Hose hook dark...

Page 4: ...arge or flooding ring missing from hose barb ensure inner discharge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer 3 Excess concentrate draw a Metering tip not in...

Reviews: