background image

Landscape Lighting

Motion SenSor inStruction Manual

Congratulations on selecting your new Landscape  
Lighting Motion Sensor. The HRL-100-MS (part number: 
06730) connects directly into the Hydro-Rain

®

 3-Station LED 

Landscape Light Controller/Transformer to provide additional 
security, comfort, and beauty to your home and yard.

Motion SenSor FeatureS:

•  Passive Infrared Motion Sensor
•  120° motion detection
•  Up to 40 ft. range
•  Wall or yard mounting (stake included)

inStallation:

tools required:
•  Wire Cutters/Strippers
•  Phillips Screwdriver
•  Two screws (if wall mount is desired)
•  Drill Bit (if wall mount is desired)
•  Power Drill (if wall mount is desired)

Yard installation:
1. Select a location in your yard, such as a flowerbed 

or garden, near an area you want motion to be 
detected

2. Insert stake until platform is flush and level with 

the ground

3. Adjust the sensor head to optimize motion 

detection, pointing it towards the area most likely 
to receive motion

note: The Motion Sensor should not be placed in 
a location that is beyond the length of its chord 
(approximately 8 ft.).

Wall installation:
1. Select a location on a wall near an area you want 

motion to be detected

2. Remove sensor head from plastic stake by sliding 

the head up

3. Install a screw into the lower pre-formed hole 

before doing the same with the upper pre-formed 
hole

4. Adjust the sensor head to further optimize motion 

detection

note: The Motion Sensor should not be placed in 
a location that is beyond the length of its chord 
(approximately 8 ft.).

connecting your Motion Sensor to terminal:
1. Separate the three wires, only enough for 

installation, connected to your motion sensor

2. Strip ½ inch (12 mm) of the plastic insulation 

off the end of each wire

3. Loosen the necessary terminal screws
4. Insert red wire into the power terminal
5. Insert black wire into the common terminal
6. Insert white wire into the appropriate station terminal
note: If installing more than one motion sensor, multiple power 
(red) wires will be inserted into the single power terminal. Multiple 
common (black) wires will be inserted into the single common 
terminal. White wires will be inserted into the appropriate station 
terminal. For motion sensor to operate, start times, stop times, and 
sensor times must be entered into your Lighting Controller.
7. Secure the wires by tightening the screws.

WarningS:

•  The main low voltage cable is intended for shallow burial—less than 6 inches 

(152 mm).

•  Warning—Risk of Electric Shock. Install all luminaries 10 feet (3.05 m) or 

more from a pool, spa, or fountain.

•  Landscape lights by Hydro-Rain

®

 do not use tungsten halogen bulbs unless 

marked for such.

•  Protect your low voltage cable by:  

•  Routing it in close proximity to the light or fitting 
•  Routing it next to a building structure (e.g. house, deck) 
•  Do not bury deeper than 6 inches (15.2 cm) in order to connect to the main  
  low voltage cable 
•  Trim the cable length so that it is attached to a connector within 6 inches  
  (15.2 cm) from a building structure, a landscape light, or a fitting.

Help:

www.hydrorain.com
Before returning this controller to your authorized Hydro-Rain

®

 distributor, 

contact Hydro-Rain Technical Service at: 1-888-493-7672.

WarrantY and StateMent:

Hydro-Rain

®

 warrants to its customers that its products will be free from defects in 

materials and workmanship for a period of five years from the date of purchase.
We will replace, free of charge, the defective part or parts found to be defective 
under normal use and service for a period of up to five years after purchase 
(proof of purchase required).
Hydro-Rain

®

 reserves the right to inspect the defective part prior to replacement.

Hydro-Rain

®

 will not be responsible for consequential or incidental cost or 

damage caused by the product failure.
Hydro-Rain

®

 liability under this warranty is limited solely to the replacement or 

repair of defective parts.
To exercise your warranty, return the unit to your authorized distributor with a 
copy of the sales receipt.
This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and 
(2) This device must accept any interference received, including interference that 
may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the 
party responsible for compliance could void the user’s authority to operate the 
equipment.

Hydro-Rain

®

915 Overland Street

North Salt Lake, UT 84054 USA

www.hydrorain.com

1-888-493-7672

[email protected]

PN 06730-24 rA

p 801 295 9820

 

f 801 951 5815

www

.fluid-studio

.net

1065 South 500 

W

est

 

Bountiful,

 Utah 84010

pr

oof no:

 

3

d

ate:

 09.14.12

des:

 SM

client:

 Orbit

sku:

 06730

upc:

 N/A

file name:

06730-24 rA

.indd

softw

are:

 InDesign CS5

colors

 

additional instructions:

· 

Accordian 

Style T

rifold 

 

· 

 

· 

color

 

non printing 

PMS

 

2955

PMS

 

????

 

color

 

non printing  

PMS

 

????

 

Registration

Black

 

Printers are responsible for 

meeting print production 

requirements

. An

changes 

must be appro

ved b

y the 

client and Fluid Studio

printed piece must meet 

designa

ted specifica

tions 

on this form

.

dimensions:

fla

t:

  w:

 13.5"

 h

7.0"

finished:

  w 

4.5"

 d

7.0"

© 2012 Fluid Studio

. T

his 

w

ork is the property of Fluid 

Studio

, and cannot be used,

 

reproduced or distributed 

in an

y w

ay without their 

express permission.

Wall Mount

2.70"

2.90"

Dimensions

Stake Mount

.

.

Red wire

Black wire

White 

wire

STATION

MOTION SENSOR

LIGHT

SENSOR

COM

PWR  COM

1

2

3

1

2

3

Reviews: