IntRoDuCtIon

Thank you for selecting the HRC-990-RS-MD Hydro-Rain

®

 sensor module. This 

sensor is built for use with the Hydro-Rain

®

 HRC-990 isolation controller only. It 

is equipped with a wire plug in feature that inserts directly into the base of the 

HRC-990 (See front cover illustration). After a set amount of rain has fallen the 

sensor engages a switch that will prevent the timer from watering. The added 

freeze sensor bonus feature will provide peace of mind by interrupting your 

sprinklers controlled by the HRC-990 timer and reduce the hazards of stand-

ing water freezing on your driveway, sidewalks, and patios when temperatures 

drop below 37˚F (3˚C). Once the rain sensor has dried sufficiently or the freeze 

sensor temperature rises above 37˚F (3˚C), the sensor allows normal sprinkler 

operation.

InStallatIon InStRuCtIonS

Mounting

The HRC-990-RS-MD sensor includes 3 mounting options.

  1. ½" Slip Adapter for mounting on a PVC riser

  2. ½" Threaded Adapter for mounting on a PVC or metal threaded riser

  3. Rain Gutter or flat surface adapter

Mount the sensor where it will be exposed to direct, unobstructed rainfall  

(but away from sprinkler spray). The switch-housing portion must be upright 

(see Figure 1).

Hints for mounting:

A. Because the wire provided with the module is 30’ long. You must install the 

sensor within 30’ of the timer.

B. Mount in the highest possible position where rain can fall directly upon the 

sensor.

C. As described in the “Adjustments and Operation” section of this manual, 

“reset rate” refers to the amount of time it takes the sensor to dry out suffi-

ciently for the sprinkler system to be allowed to come back on. The mounting 

location will affect this rate and should be taken into consideration should 

extreme conditions exist. For example, mounting the sensor on a very sunny, 

southeastern end of a building may cause the sensor to dry out sooner than 

desired. Similarly, mounting on the northern end of a building with constant 

shade may keep the sensor from drying soon enough. Some experimentation 

and use of the “vent ring” (as described later) will usually yield satisfactory 

results. 

Once the sensor is mounted, run the wire and wiring jack to the HRC-990 timer. 

Plug the jack into the base of the timer marked “Sensor” .  The rain sensor is 

now ready for use. (See Figures 2 and 3)

Wiring

Important: The sensor is sold and designed for for use with the HRC-990 timer 

only. Any alteration of this product for use with 24 Volt irrigation timers voids the 

warranty. 

opeRatIon CHeCk to VeRIfy CoRReCt WIRIng

Turn on one zone of the sprinkler system that is visible while you are in reach  

of the sensor. Manually depress the spindle at the top of the sensor until you  

hear the switch “click” off. The sprinkler zone should stop instantly. If it does  

not, check wiring jack to insure proper contact is made with the HRC-990 base. 

aDjuStMentS anD opeRatIon

The sensor can keep the irrigation system from starting or continuing after 

rainfall quantities of ¹⁄

8

", ¼", ½", ¾", or 1". To adjust to the desired quantity of 

rainfall, rotate the cap on the switch housing so that the pins are located in the 

proper slots (See Figure 4). Do not forcibly twist the cap as this might break the 

pins. The time that it takes the sensor to reset for normal  sprinkler operation 

after the rain has stopped is determined by weather conditions (wind, sunlight, 

humidity, etc.). These conditions will determine how fast the hygroscopic discs 

dry out, and since the landscape is also experiencing the same conditions, their 

respective drying rates will roughly parallel each other. There is an adjustment 

capability on the sensor that will slow down the reset rate. By turning the “vent 

ring” (See Figure 4) to completely or partially cover the ventilation holes, the 

hygroscopic discs will dry more slowly. This adjustment can compensate for an 

“overly sunny” installation location or peculiar soil conditions. Experimenting 

with the vent rings will best determine the ideal vent setting.

DISplay

When the optional Rain/Freeze Sensor is installed with the HRC-990 Hydro-

Rain

®

 timer and the unit is operating under <DELAY>, <AUTO> or <MANUAL> 

mode, the unit will enter a special <RAIN DELAY> operation where the LCD will 

display the following:

fReeze SenSoR optIon

The temperature at which the optional freeze off sensor feature is activated is 

37°F ±2° (3°C ±1°) (temperature range adjustment is not available).

BypaSSIng tHe SenSoR

Should you desire to bypass the operation of the sensor for any reason  

(i.e., turn on your system even though the sensor has shut “off” due to rainfall or 

temperature), unplug the sensor from the bottom of the timer. Plug it back in to 

resume normal sensor operation.

MaIntenanCe

There is no required maintenance for the unit. The sensor does not have to be 

removed or covered for winterizing purposes. All parts are easily replaceable if 

they become damaged or lost. The spindle assembly is designed to stay with the 

cap. Do not pull them apart. 

tRouBleSHootIng

Follow these simple checks before replacing your sensor:

System will not come on at all:

A. Check to see that the sensor discs are dry and the switch “clicks” on and off 

freely by pressing the top of the spindle.

B. Look for breaks in the wire leading to the sensor and check all wire junctions.

System will not shut off even after heavy rainfall:

A. Check wiring for correct installation. (See “Operation Check to Verify  

Correct Wiring”.)

B. Check sensitivity setting on sensor, and move the cap to a more  

sensitive setting. The sensor is an accurate rain gauge and can be  

verified by setting up a “tube” type rain gauge in the same vicinity and  

making periodic readings.

C. Check for obstructions to rainfall such as overhangs, trees or walls.

1

2

3

4

SOLAR

RAIN/
FREEZE
SENSOR

Figure 2

Summary of Contents for HRC-990-RS-MD

Page 1: ...s additional instructions Font sizes cannot be smaller than 7 pt color non printing PMS 2955 PMS color non printing PMS Registration K Printers are responsible for meeting print production requirements Any changes must be approved by the client and Fluid Studio printed piece must meet designated specifications on this form dimensions flat w 7 25 h 4 5 finished w 7 25 d 0 h 4 5 2007 Fluid Studio Th...

Page 2: ...it does not check wiring jack to insure proper contact is made with the HRC 990 base Adjustments and Operation The sensor can keep the irrigation system from starting or continuing after rainfall quantities of 8 or 1 To adjust to the desired quantity of rainfall rotate the cap on the switch housing so that the pins are located in the proper slots See Figure 4 Do not forcibly twist the cap as this ...

Page 3: ...it does not check wiring jack to insure proper contact is made with the HRC 990 base Adjustments and Operation The sensor can keep the irrigation system from starting or continuing after rainfall quantities of 8 or 1 To adjust to the desired quantity of rainfall rotate the cap on the switch housing so that the pins are located in the proper slots See Figure 4 Do not forcibly twist the cap as this ...

Page 4: ...ain liability under this warranty is limited solely to the replacement or repair of defective parts To exercise your warranty return the unit to your dealer with a copy of the sales receipt The microswitch is UL approved for electrical safety 1 2 3 4 SOLAR RAIN FREEZE SENSOR Figure 3 The Module to the HRC 990 Controller Base Figure 1 Mounting Rain Sensor Figure 4 Parts Diagram A Cap B Spindle Asse...

Reviews: