EN_TXV_INDEXABLE_2016_06 

 

 

Instructions TXV Indexable 

Read before installation of the pump 

 

 

                                            

IMPORTANT! 

 

 

 

 

 

 

 

 

 

 
 
 

 
 
 
 

        1       2 

 3 

 

 

 

            4 

                  5 

 
HOW TO CHANGE ROTATION DIRECTION ON THE PUMP: 
Remove the 4 screws. 1 
Remove the 2 flange halves  2 
Remove the fitting 3 
Switch place on screw  4   and plug  5   and reassemble fitting on the other port 
NOTE: Do not rotate the pump shaft before the set screw   4   is in place. 
NOTE: Rotation adjustment screw  4  is always the output side of the pump. 

Calculation of suction hose: 

Flow 

Size suction hose 

0-65 

1 ½” / 38 mm 

0-120 l/min 

2” / 50 mm 

120-160 l/min 

2 ½” / 63 mm 

160-250 l/min 

3” / 76 mm 

This is valid when tank is place above the pump. 
When tank is placed beside or under the pump the max flow/ hose size should be reduced.  

LS Drainage: 
Connect at least 
10 mm (½ ") hose 
direct to tank to 
prevent back 
pressure. 

Pressure limit. Factory set at ~100bar 

Stand-by Pressure control. Factory set at 30 Bar 

 

Connect all hoses to the pump. 
The pump should get oil through the 
drainage hose. Make sure the pump has oil 
using the bleed screw. 
Open the bleed screw (don’t unscrew 
completely) and check if oil comes out. 
If no oil comes, remove the screw 
completely and manually fill the pump 
with oil. Mount the screw and tighten. 
Start up the hydraulic system on low speed 
Start an operation to evacuate any 
remaining air in the tubing and pump. 
Bleed the LS line. 
 

Bleed Screw 

LS Connection on opposite 
side of regulator 

CCW 

CW 