Page 1: ... X Pro Spot Extractor MA51H Power X Pro Spot Extractor with Heat Operating Manual Power X Pro Spot Extractor Hydro Force 4282 South 590 West Salt Lake City UT 84123 801 268 2673 801 268 3856 FAX Revised 10 08 2014 ...

Page 2: ...y 6 SECTION 2 Operation Procedures Electrical Supply 7 Water Supply Chemicals 7 Solution Vacuum Hoses 7 Starting System Switches 8 Shutdown Procedures 9 Troubleshooting 10 11 Solution Flow Path MA51 12 Solution Flow Path MA51H 13 Wiring Diagrams MA51 14 Wiring Diagrams MA51H 16 SECTION 3 Maintenance Technical Maintenance 18 Parts 21 o MA51 22 o MA51H 27 o Hoses Tool 34 Warranty 35 ...

Page 3: ...e machine and to ensure that the equipment operates at its maximum performance level All users must read and understand this manual completely before operating the machine Always maintain this manual in legible condition adjacent to the Power X Pro Spot Extractor or place in a secure location for future reference Any questions pertaining to the operating or servicing of this unit should be directe...

Page 4: ...r Draw 6 42 7 3 amps Power X Pro Spot Extractor with Heater Model MA51H Height 24 Length 21 Width 10 Weight 30lbs Solution Tank Capacity 3 gallon Recovery Tank Capacity 3 gallon Power Cord 20 foot 16 3 Solution Outlet 1 4 Male Quick Connect Solution Pump Flojet ET508224 HP pump 55 psi 0 37gpm Vacuum Motor AMETEK Lamb 4 8 Diameter Peripheral discharge Two Stage 87 7cfm 76 5 WC Heater 600 Watt Power...

Page 5: ...llustrated in the sketch to the right Make sure that the machine is connected to an outlet having the same configuration as the plug No plug adapter should be used with this machine The power cord supplied with this machine is properly sized to handle the electrical load of this machine and properly grounded as described above Any extension cords used with this machine must be similarly sized and ...

Page 6: ...chemical compatibility Contact your distributor or Hydro Force if you have questions regarding the compatibility of your chemicals with the machine Do not clean with solutions that are at temperatures above 100ºF Rinse the solution tank chemical system and pump with fresh water after each day s use Do not allow pump to run dry Always maintain adequate solution level to supply solution pump Solutio...

Page 7: ...to a level approximately 4 inches from the top of the tank The water temperature should not exceed 120 F Measure and add the appropriate amount of the desired liquid chemical to the water in the solution tank The amount of chemical will vary depending on the type of chemical used the amount of water in the tank and the material being cleaned consult the chemical packaging for specific mixture rati...

Page 8: ...teady check the hose from the solution tank to the pump and the filter screen for clogging kinks or restrictions Clean or replace hose and or filter and Turn switch ON Check the valve operation and the jet on the tool for flow restriction that can affect solution flow If you are having trouble with the pump refer to the trouble shooting guide or contact your distributor for advice or assistance On...

Page 9: ... to release pressure from the hose before disconnecting solution hose Drain any remaining water from the solution tank and the recovery tank and dispose in sanitary drain Drain the recovery tank by pouring the water out of the vacuum barb Do not attempt to pour the water out the recovery tank hatch cover opening Do not use the same bucket to drain the tank that you use to fill the tank Remove the ...

Page 10: ...e Tighten clamps or replace fittings Solution tank empty Add water to tank Check repair auto fill assembly Pump faulty Repair or replace pump AP30 Tool valve faulty Repair or replace valve Quick connects or hoses restricted Clean out or replace quick connects and or hoses Can t connect Pressure in lines Turn off pump Release pressure solution hose Quick connects faulty Replace quick connects AH101...

Page 11: ...Repair or replace float shutoff Recovery tank damaged Replace recovery tank Tool won t Jet clogged Clean out or replace jet spray low or Inline filter clogged Clean out or replace filter if so equipped uneven spray Jet worn Replace jet Jet not aligned properly Re align jet Tool valve faulty Repair or replace valve Quick connects or hoses restricted Clean out or replace quick connects and or hoses ...

Page 12: ...12 Solution Tank Outlet Quick Connect Denotes Water flow in pressure hose Denotes incoming water flow MA51 Solution Flow Path Pump AP30 ...

Page 13: ...es Cold Water flow in pressure hose Denotes incoming water flow MA51H Solution Flow Path Pump AP30 Denotes Heated Water flow in pressure hose HEATER PRESSURE RELIEF VALVE Denotes Heated Water by pass flow from heater pressure relief CHECK VALVE ...

Page 14: ...4 MA51 Wiring Diagram Standard Power Switch POWER CORD OLD STYLE SINGLE SWITCH PUMP VACUUM AV06 Pump Switch POWER CORD NEW STYLE DUAL SWITCH PUMP VACUUM AV06 Vacuum Switch YELLOW WHITE GREEN GROUND SCREW ...

Page 15: ...on Pump Switch Vacuum Switch When the switch is turned to the ON position power is supplied to the solution pump motor and vacuum motor Power Cord Old Style Single Switch New Style Dual Switch Power Cord Vacuum Switch Solution Pump Switch ...

Page 16: ...Pump Switch Heater Switch Vacuum Switch POWER CORD HEATER 600w VACUUM AV06 PUMP Manual Reset Hi Limit Temperature Switch 10 0814 B Auto Reset Temperature Control Switch 10 0814 HEATER ELEMENT PSA101500B New Style Heater Only GROUND SCREW ...

Page 17: ...tor only When not using solution Extracting only do not turn this switch ON Heater Switch When the switch is turned to the ON position power is supplied to the solution heater only Always turn pump switch on first and be sure water is flowing to the tool before turning heater ON Turn heater off and spray tool for a minute to cool off heater before turning pump off When not using solution Extractin...

Page 18: ... before testing or repairing switches or power cords Failure to do so may result in severe personal injury or death OPERATION INTERVAL Page CLEAN VACUUM SHUTOFF ASSEMBLY Daily After Each Job 19 RINSE OUT RECOVERY TANK Daily 19 FLUSH SOLUTION TANK AND PUMP Daily 19 CLEAN PUMP INLET FILTER Daily 19 DESCALING HEATER MA51H ONLY As needed 20 REMOVING BASE TO ACCESS HEATER MA51H ONLY As needed 20 STORAG...

Page 19: ...the tank smelling better 1 Remove the recovery tank lid 2 Use a hose to rinse the dirt and debris out of the recovery tank 3 Spray the tank with a deodorizer or disinfectant 4 Replace the recovery tank lid 5 Dispose of the dirty water and debris FLUSH SOLUTION TANK AND PUMP 1 Pour one gallon of clean water into the solution tank Slosh the water around in the tank to clean tank and pour water out a...

Page 20: ...f the Power X Pro Spot Extractor Storage Prep and Freeze Protection Procedures Your Power X Pro Spot Extractor must be protected from freezing Freezing can cause serious damage to the pump pump out auto fill float valve and any other component containing water If the Power X Pro Spot Extractor is transported or stored in freezing temperatures the following procedures should be performed 1 In a sep...

Page 21: ...21 Parts Replacementpartsavailableforrepairof yourPowerXProSpotExtractor Section 3 Power X Spotter Pump AP30 Power X Spotter Vacuum Motor AV06 SOLUTION OUTLET 1 8 FPT SOLUTION INLET 1 8 FPT ...

Page 22: ...70 Nipple 1 8 Hex 1 AH102B Quick Connect 1 4 Male 1 PAF03 Quick Connect 1 8 Male 1 10 0434 Threaded Hose for Spotter 2 5 NA0839 Barb Nylon Straight 1 8 NPT X 4 NA0840 1 8 Strainer for Spotter 1 AP30 Pump For Spotter 1 10 0301 L Bracket For Spotter 1 10 0435 Oetiker Clamp 5 10 0303 Roller Blade Wheel 2 10 0387 5 16 x 1 Socket Head Bolt For Wheels 2 10 0022 Screw 1 10 0017 Deflector Screw 1 10 1028 ...

Page 23: ...N BARB ELBOW 1 8 MPT 10 0406 1 4 ID THREADED HOSE 10 0434 VACUUM GASKET PS10 1030 VACUUM SCREEN 10 0386 VACUUM MOTOR AV06 MA51 SCREW 5 16 X 1 SOC HD FOR WHEEL MOUNT 10 0387 QTY 2 SCREW VAC MOTOR MOUNT QTY 2 10 0014 PLATE VAC MOTOR MOUNT 10 1024 SCREW VAC MOUNT PLATE QTY 2 10 0380 OETIKER HOSE CLAMP 10 0435 NA0840 ...

Page 24: ...LBOW 1 8 MPT 10 0406 1 4 NYLON BARB X 1 8 MPT NA0839 ACORN STRAINER NA0840 1 4 MALE QUICK CONNECT AH102B 1 4 ID HOSE 10 0434 MA51 1 4 X 1 8 HEX NIPPLE BR130 OETIKER HOSE CLAMP 10 0435 1 8 NPT BULKHEAD FITTING PP11 800091 ...

Page 25: ...ET 10 0302 A SCREWS 10 0419 QTY 6 SPOTTER HATCH COVER BOTTOM VIEW VACUUM FILTER 10 0431 SPOTTER COVER FLOAT 10 0304 SPOTTER HANDLE ASSEMBLY NM5090 HANDLE HANDLE SLIDE ASSEMBLY 50 0001A RECOVERY TANK NM5090 RT SOLUTION TANK NM5090 ST MA51 ...

Page 26: ... BACK SWITCH PLATE 10 1025 SWITCH PDRI01 POWER CORD 10 0448 B STRAIN RELIEF 10 0027 NUT 10 0027 A LATCH KEEPER 10 0400C SCREWS 10 0383 QTY 2 SCREW 6 32 X 1 4 10 0383 Old style 4 New Style 2 SOLUTION TANK NM5090 ST RECOVERY TANK NM5090 RT SCREW FOR BASE PLATE 10 0482 FLAT WASHER NM5032 Old style 4 New Style 2 LATCH 10 0400D SCREWS 10 0383 QTY 4 GROUND SCREW NM4061 NUT NM4081 ...

Page 27: ...pple 1 8 Hex Brass 1 PSA100901 Pressure Relief Valve 175psi 1 BR220 Brass Plug 1 8 1 NM5087 Bulkhead Fitting 1 4 Brass 2 BR020 Barb 3 8 x 1 4 MPT Brass 4 PH07 Hose Clamp 6 10 0843 Hose 3 8 ID Black LP 1 10 0434 Threaded Hose for Spotter 1 NA0839 Barb Nylon Straight 1 8 NPT X 1 4 Barb 4 NA0840 1 8 Strainer for Spotter 1 10 0301 L Bracket For Spotter 1 10 0828 90 Deg Brass Elbow 1 8 MPT 1 10 0022 Sc...

Page 28: ... 0303 Roller Blade Wheel 2 10 0822 Exhaust Grate 2 10 0419 A Screw For Exhaust Grate 2 10 0014 Motor Screws 2 10 0380 Screw 10 32 x 3 8 2 10 1024 Vac Motor Mounting Plate 1 AV06 Vacuum Motor 1 10 0386 Stamped Motor Screen 1 PS10 1030 Spotter Motor Gasket 1 10 0027 A Strain Relief Nut For Spotter 1 T WBLA Black Wire 10 0027 Pigtail Strain Relief Spotter 1 10 0448 B 20 Ft Spotter Air Mover Cord 1 PD...

Page 29: ... 10 0419 QTY 6 SPOTTER HATCH COVER BOTTOM VIEW VACUUM FILTER 10 0431 SPOTTER COVER FLOAT 10 0304 SPOTTER HANDLE ASSEMBLY NM5090 HANDLE HANDLE SLIDE ASSEMBLY 50 0001A RECOVERY TANK NM5090 RT SPOTTER BASE W HEAT SP 3 HS GRNGRAN MA51H SOLUTION TANK NM5090 ST ...

Page 30: ...POWER CORD 10 00448 B SPOTTER BASE MA51H SP 3 HS GRNGRAN VENT GRATE SCREWS 10 0419 A QTY 2 SWITCH PDRI01 MA51H BACK SWITCH PLATE 10 1026 WHEELS QTY 2 10 0303 SCREWS 10 0387 SCREW 6 32 X 1 4 10 0383 MA51H RECOVERY TANK NM5090 RT LATCH KEEPER 10 0400 C SCREWS 10 0383 QTY 2 GROUND SCREW NM4061 NUT NM4081 ...

Page 31: ...B 3 8 X 1 4 MPT BR020 HOSE 3 8 ID HI TEMP BLACK 90 DEGREE BRASS ELBOW 3 8 BARB X 1 8 MPT 10 0828 VACUUM MOTOR AV06 VACUUM SCREEN 10 0386 VACUUM MOTOR AV06 VACUUM GASKET PS10 1030 PLATE VAC MOTOR MOUNT SCREW VAC MOUNT PLATE QTY 2 10 0380 SCREW VAC MOTOR MOUNT QTY 2 10 0014 ...

Page 32: ...K VALVE 1 4 MPT NM5069 MA51H Heater Assembly HEATER 600W PSA100910 COMPLETE WITH FITTINGS PRESSURE RELIEF VALVE PSA100901 HEATER ELEMENT ONLY PSA101500B HEATER OUTER SHELL ONLY PSA100900 BULKHEAD FITTING 1 4 NM5087 BARB 3 8 X 1 4 MPT BR020 HOSE HP 1 4 ID HI TEMP BLUE 1 4 JIC FITTINGS PSA001 ELBOW 90 1 4 FPT X 3 8 BARB Heater is secured to Spotter Base with two screws Flat Washers 2 SCREW 10 32 x 1...

Page 33: ...ING 1 4 NM5087 NIPPLE 1 4 HEX BR072 RECOVERY TANK NM5090 RT ACORN STRAINER 1 8 FPT NA0840 BARB 1 4 X 1 8 MPT NA0839 1 4 ID HOSE 10 0434 SPOTTER BASE MA51H SP 3 HS GRNGRAN SOLUTION TANK NM5090 ST 1 4 MALE QUICK CONNECT AH102B ...

Page 34: ...1 1 8 Hose End for 3 16 hose 1 7 AH02 1 4 Hose End for 3 16 hose 1 8 100003 Wire Tie Black 7 5 9 AH90 3 8 LP Gray Solution Hose Sold per foot 0 5 10 PMV124V5 Solution Valve with lever mounting bracket 1 11 PMF8002 Tee Jet for hand tool 8002 1 12 PMF011 Retaining Plate for jet on hand tool 1 13 BR304 Compression fitting 1 8 MPT 1 NS PMV124V5B Valve Repair Kit 1 AW55H HOSE TOOL ASSEMBLY 1 11 10 2 3 ...

Page 35: ...rranty shall not apply to defects resulting from improper operation lack of maintenance unauthorized modification chemical incompatibility misuse abuse or exposure to freezing temperature conditions It does not cover normal wear items such as o rings valve seals pump seals hoses jets cords batteries or other items which require replacement as a result of ordinary usage To obtain warranty service f...