Yoke Locks may become fully engaged in fixture head during shipment or after installation and not allow for fixture
re-aiming. This is a normal operation and may require the Yoke Locks to be dis-engaged for re-aiming.
To dis-engage Yoke Locks:
- Loosen Yoke Lock center fasteners on each yoke lock
2 - Locate Yoke Lock/Fixture interface disengagement slots. Slots are located perpendicular to yoke axis (Fig.1)
- Insert large flat blade screwdriver into slots and pull screwdriver handle away from fixture body releasing the
Yoke Lock.
- Adjust fixture and re-tighten center Yoke Lock fasteners.
TPS3 WIRING DIAGRAM
©2014 Acuity Brands Lighting, Inc.
3/13/14
INS-TPS3
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION
WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a
reference dimension: “Used for information purposes only. It does not
govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
20660 Nordhoff St., Suite B
Chatsworth, CA 91311
Phone: 866.533.9901
Fax: 866.533.5291
www.hydrel.com
TPS3 SERIES
YOKE MOUNT
WIRING
Installation should be performed by a qualified
electrician in accordance with the National Electrical Code
and relevant local codes.
INSTALLATION INSTRUCTIONS
ATTENTION: DISCONNECT POWER BEFORE SERVICING
WARNING
- TO REDUCE RISK OF FIRE, USE APPROPRIATE LAMP
Lamp information is found inside luminaire. Removing the reflector may be necessary to view lamp information.
SUITABLE FOR WET LOCATION
MINIMUM 90°C SUPPLY CONDUCTORS
LES FILS D’ALIMENTATION DOIVENT CONVENIR POUR 90°C
p
!
YOKE ADJUSTMENT DIAGRAM
Black
White
Green
(+) Red
(+) White
(-) Black
(-) Green
Bare Wire - Earth Ground
Standard Fixture
Dimming Fixture
Wire
Power Supply
A
B
C
D
A
B
C
D