10-1: Troubleshooting
RX-20
10 - Troubleshooting
Low Vacuum Flow at the Cleaning Heads
1.0
Possible Cause
Solution
1.1 Hub not sealing properly.
Replace felt seal with a lubricated one.
1.2 Restricted air flow.
Remove hoses from the vacuum shoe and skid
assembly, and clear them of debris.
1.3 Low vacuum flow from power.
Refer to Troubleshooting section of source
equipment manual.
Low Water Flow at Cleaning Heads (indicated by irregular Water Temperature)
2.0
Possible Cause
Solution
2.1 Restricted jets.
Remove jets and clear them of debris.
2.2 Clogged water strainer.
Remove water strainer and clean.
2.3 Kinked or clogged solution
hose.
Remove hose. Repair or replace.
2.4 Cleaning hub not properly
threaded.
Remove cleaning hub from shaft to shaft. Clean
and rethread onto shaft.
Water Leak at Rotary Union
3.0
Possible Cause
Solution
3.1 foreign matter in rotary union
seal.
dismantle rotary union. Clean. Re-assemble and
install.
Water Leak at Valve
4.0
Possible Cause
Solution
4.1 Ruptured plunger or valve
O-ring.
Repair or replace damaged plunger, O-ring, seal.
Check for freeze damage.
4.2 Ruptured plunger or valve
O-ring.
Repair or replace damaged plunger, O-ring, seal.
Check for freeze damage.
Summary of Contents for RX-20 700-041-006
Page 2: ......
Page 10: ...Introduction 1 4 RX 20...
Page 14: ...Machine Specifications 2 4 RX 20...
Page 16: ...Assembly Instructions 3 2 RX 20...
Page 28: ...Machine Maintenance 6 6 RX 20...
Page 29: ...7 1 Electrical Diagrams RX 20 7 Electrical Diagrams Wiring Diagram 120 V 60 Hz Figure 7 1 6037...
Page 30: ...Electrical Diagrams 7 2 RX 20 Wiring Diagram 230 V 50 Hz Figure 7 2 4503 Rev A...