Installation and Maintenance Instructions.

THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.

Owner / installer: 

The life of this apparatus and its efficiency will be increased if 

its use and maintenance is carried out in accordance with these instructions and 
current statutory requirements. The installation and initial adjustments should be 
carried out by a qualified and competent technician. Hydor Limited should be 
consulted before substituting or fitting parts from another manufacturer. It is the 
responsibility of the installer to verify that the installation is in accordance with all 
current statutory requirements and the owner is given the current User’s Manual.

Any modifications to the fan or its installation, even the smallest 
modification, change or elimination of security components or pieces that 
influence the efficiency or loss of ventilation, will result in the CE Certification 
and Hydor’s warranty being cancelled.

1.   General

1.1  It is important these Installation and Maintenance Instructions are fully  
 

adhered to.

1.2   Full details of the unit supplied are shown on the product nameplate. If in  
 

doubt about any detail contact Hydor or its agents for clarification.

1.3   All electrical installation must be carried out by suitably qualified and  
 

competent personnel in accordance with all current statutory  

 requirements.
1.4   These instructions cover only the Hydor product and do not include the  
 

supply or installation of any safety equipment that may be required e.g.  

 

adequate guarding or protection from rotating parts and proper electrical  

 isolation.
1.5   Any declarations made by Hydor about product installation and safety, are
 

dependant on the fan equipment being used within installations which  

 

themselvesmeet the requirements of the relevant Standards and Directives  

 

of your region.

HXP Plate Fan

incorrect

correct, minimum height 5mm

Summary of Contents for HXP45041

Page 1: ...that influence the efficiency or loss of ventilation will result in the CE Certification and Hydor s warranty being cancelled 1 General 1 1 It is important these Installation and Maintenance Instructions are fully adhered to 1 2 Full details of the unit supplied are shown on the product nameplate If in doubt about any detail contact Hydor or its agents for clarification 1 3 All electrical installa...

Page 2: ...eck for any damage Ensure that the impeller is free to rotate 2 3 If there are any queries concerning the fan equipment Hydor should be contacted prior to the installation 2 4 The fan must be securely mounted in the desired position to suit the application The fan can be mounted at any angle 2 5 Check the details on the motor rating plate to ensure that the correct power supply voltage frequency a...

Page 3: ...arings are of the sealed for life type and will not need a detailed inspection WARNING Only a suitably qualified and competent person may carry out maintenance after the electrical supply has been isolated Particular care must be taken when automatic switching controls are used 5 Wiring 5 1 Check that the fan unit supplied is suitable for the supply voltage and type of fan being replaced 5 2 Rem o...

Page 4: ...E U4 BROWN U1 RED Z1 YELLOW Z2 BLUE U3 U2 Z1 Z2 U1 U4 CAPACITOR L BROWN N BLUE LINK LINK LINK CLOCKWISE ROTATION 1Ph 50Hz WN E FORM B AIRFLOW MODELS CHANGE Z1 BLUE Z2 YELLOW VERSE THE MOTOR ROTATION E GREEN YELLOW EN YELLOW U2 BLACK 220V TO 240V 1Ph 50Hz SUPPLY U3 WHITE U4 BROWN U1 RED Z1 YELLOW Z2 BLUE U3 U2 Z1 Z2 U1 U4 CAPACITOR L BROWN N BLUE LINK LINK LINK CLOCKWISE ROTATION 220V TO 240V 1Ph 5...

Page 5: ...OTATION LINK LINK L3 L2 L1 SWAP ANY 2 SUPPLY PHASES E GREEN YELLOW 380V TO 440V 3Ph 50Hz SUPPLY 230V 3Ph 50Hz SUPPLY W1 U2 U1 V1 W2 V2 R DELTA 2 2 2 TO CHANGE MOTOR ROTATION LINK LINK LINK L3 L2 L1 L3 L2 L1 SWAP ANY 2 SUPPLY PHASES E GREEN YELLOW E GREEN YELLOW 380V TO 440V 3Ph 50Hz SUPPLY 230V 3Ph 50Hz SUPPLY W1 U2 U1 V1 W2 V2 DELTA O CHANGE MOTOR ROTATION LINK LINK LINK 3 2 1 L3 L2 L1 WAP ANY 2 ...

Page 6: ... 615 169 293 100 15 10 HXP56043 560 577 620 725 670 182 321 100 15 10 HXP56063 560 577 620 725 670 169 323 100 15 10 HXP63061 630 647 700 805 750 189 328 105 20 10 HXP63063 630 647 700 805 750 189 328 105 20 10 HXP63083 630 647 700 805 750 187 326 105 20 10 HXP71061 710 725 765 850 810 204 341 103 27 10 HXP71063 710 725 765 850 810 191 328 103 27 10 HXP80061 800 817 880 973 910 202 353 105 30 10 H...

Page 7: ...Notes ...

Page 8: ...ns Note Number carriage paid for further examination Hydor Ltd Hydor Unit 8 Parkers Close Downton Business Centre Downton Salisbury Wiltshire SP5 3RB UK Tel 44 0 1725 511422 Email info hydor co uk Web www hydor co uk idealair group Unit 1 Building 1 Sydney Corporate Park 85 O Riordan Street Alexandria NSW 2015 Tel 61 02 8073 3310 Fax 61 02 8073 3320 Email info idealairgroup com au AMS 11 Ingrid Ro...