background image

Installation and Maintenance Instructions.

THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.

Owner / installer:

 

The life of this apparatus and its efficiency will be increased if 

its use and maintenance is carried out in accordance with these instructions and 
current statutory requirements. The installation and initial adjustments should be 
carried out by a qualified and competent technician. Hydor Limited should be 
consulted before substituting or fitting parts from another manufacturer. It is the 
responsibility of the installer to verify that the installation is in accordance with all 
current statutory requirements and the owner is given the current User’s Manual.

Any modifications to the fan or its installation, even the smallest 
modification, change or elimination of security components or pieces that 
influence the efficiency or loss of ventilation, will result in the CE Certification 
and Hydor’s warranty being cancelled.

HEB Plate Fan

incorrect

correct, minimum height 5mm

Please take note of the following symbols used within this document:

 Warning:

 Hazards associated with electric current and high voltages

 Important:

 Important information

Hydor’s policy is one of continual improvement and the right to change a specification at any time 
without notice is reserved. Whilst every care has been taken to ensure that the contents of this 
document are correct at time of publication, Hydor shall be under no liability whatsoever in respect 
of such contents. 

Hydor cannot guarantee the operation of any equipment unless all documented instructions are 
complied with, without variation.  
 
Hydor is a registered trademark of Hydor Ltd and is a member of Elta Group. All other trademarks, 
trade names or company names referenced herein are the property of their respective owners. 

Summary of Contents for HEB

Page 1: ...on of security components or pieces that influence the efficiency or loss of ventilation will result in the CE Certification and Hydor s warranty being cancelled HEB Plate Fan incorrect correct m Please take note of the following symbols used within this document Warning Hazards associated with electric current and high voltages Important Important information Hydor s policy is one of continual im...

Page 2: ...lations which themselves meet the requirements of the Standards and Directives of your region 2 3 This product is not intended to be operated by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the product safely Young children should be supervised to ensure that they do not play with the appliance 2 4 Adequate site pl...

Page 3: ...ried out by suitably qualified and competent personnel in accordance with local regulations 4 1 The HEB range of fans is normally supplied assembled The single phase units are supplied with the Capacitor loose 4 2 The fan must be securely mounted in the desired position to suit the application The fan can be mounted at any angle 4 3 Precaution must be taken to locate any exhaust discharge terminal...

Page 4: ... local facility 5 8 The new fan can now be fitted as follows 5 9 Lift the new HEB fan into the original mounting place 6 0 The fixing holes will line up exactly to the HE fan fixing points for 630mm and 710mm models When replacing the 760mm HE with a 710mm HEB the mounting holes will move slightly 6 1 Ensure the HEB fan assembly is adequately supported 6 2 Fix the HEB fan assembly into the apertur...

Page 5: ...by the 4 plate mounting holes but by fixings through the return flange around the outside of the HE fan plate If this is the case there are 2 options for fan replacement Option 1 Return flanges are available as an optional extra and can be purchased at the time of order These will be fitted to the plate ready for you to install There will not be any fixing holes in the return flange supplied and t...

Page 6: ...nd 710mm models HE 760mm models will required these holes drilling out Option 2 The existing HE fan plate can be left in situ The motor arms and propeller can be removed The plate could then be cut down in situ so that the new HEB plate fan will use the existing plate 4 point fixings to locate it All other parts of the replacement instructions are still valid IMPORTANT The unit is heavy Use correc...

Page 7: ...ed through a speed regulation device please refer to the relevant control device instructions or contact Hydor 8 4 Check that the motor amperage draw does not exceed the nameplate rating 8 5 Means for electrical disconnection must be incorporated in the wiring installation in accordance with the relevant wiring and electrical regulations 8 6 The capacitor should be installed as per the electrical ...

Page 8: ...50Hz SUPPLY U3 WHITE U4 BROWN U1 RED Z1 YELLOW Z2 BLUE U3 U2 Z1 Z2 U1 U4 CAPACITOR L BROWN N BLUE LINK LINK LINK CLOCKWISE ROTATION 1Ph 50Hz WN E FORM B AIRFLOW MODELS E GREEN YELLOW EN YELLOW U2 BLACK 220V TO 240V 1Ph 50Hz SUPPLY U3 WHITE U4 BROWN U1 RED Z1 YELLOW Z2 BLUE U3 U2 Z1 Z2 U1 U4 CAPACITOR L BROWN N BLUE LINK LINK LINK CLOCKWISE ROTATION 220V TO 240V 1Ph 50Hz SUPPLY CAPACITOR L BROWN N ...

Page 9: ...S E GREEN YELLOW 380V TO 440V 3Ph 50Hz SUPPLY 230V 3Ph 50Hz SUPPLY W1 U2 U1 V1 W2 V2 R DELTA 2 2 2 TO CHANGE MOTOR ROTATION LINK LINK LINK L3 L2 L1 L3 L2 L1 SWAP ANY 2 SUPPLY PHASES E GREEN YELLOW E GREEN YELLOW 380V TO 440V 3Ph 50Hz SUPPLY 230V 3Ph 50Hz SUPPLY W1 U2 U1 V1 W2 V2 DELTA O CHANGE MOTOR ROTATION LINK LINK LINK 3 2 1 L3 L2 L1 WAP ANY 2 SUPPLY PHASES E GREEN YELLOW E GREEN YELLOW ...

Page 10: ...t once every 12 months is recommended to ensure that the motor fan blades and supporting guards are clean Any build up of dust and deposits on the blades motor or guards should be removed using a non abrasive cleaner Failure to keep the unit clean can lead to overheating and damage which is not covered by the warranty 11 2 All fastenings should be checked for tightness In addition all rotating ite...

Page 11: ...Notes ...

Page 12: ...e goods must be inspected by a Hydor official and if necessary returned with a Returns Note Number carriage paid for further examination Please see the Hydor warranty claim booklet for more information should you need to return your purchase Hydor Ltd Hydor Unit 8 Parkers Close Downton Business Centre Downton Salisbury Wiltshire SP5 3RB UK Tel 44 0 1725 511422 Email info hydor co uk Web www hydor ...