Unit setup/connection
Unit setup/connection
NOTICE
Danger of tipping over / danger of slipping due to vibrations
The unit will be damaged
►
Before starting it up, put the unit on a stable, horizontal surface.
Place the unit on a horizontal and level surface which is well ventilated.
Install the suction port connection at the highest part of the tank. This
ensures that the oil phase located at the surface is reached.
Install the return line as far as possible from the suction point in order to
obtain an optimum intermixing of the tank contents.
Take the following steps to prepare the unit for operation:
1. Check that the power supply cable is undamaged. Replace damaged
cables immediately.
2. Check the connecting lines for leaks. Eliminate any leakages
immediately.
3. Check and insert the filter element. For details, see page 46.
4. Check and insert the coalescing element. For details, see page 58.
5. The unit is ready for the next steps on the following pages.