3 | Filter unit/filter housing over-view
HYDAC FILTER SYSTEMS GMBH
30 / 100
MoWa OLF-5 3433222d en-us web
3.5 Technical Data
The technical data of the filter unit is as follows:
Bypass opening pressure
for the filter element
≈ 3.5 bar
Permissible fluid contamina-
tion
< 12 NAS according to ISO4406
Class 23/21/18
Flow rate and
permitted operating pres-
sure
OLF-5-…
=5 l/min
3.5 bar
OLF-5/4 /
OLF-10/4
=5 l/min
4.5 bar
OLF-5/15 /
OLF-10/15
=15 l/min
4.5 bar
Permissible viscosity range OLF-5-S
=15 … 150 mm²/s
OLF-5/4 /
OLF-10/4
=15 … 7000 mm²/s
OLF-5/15 /
OLF-10/15
=15 … 1000 mm²/s
Permissible pressure at suc-
tion port (IN)
-0.4 … 0.6 bar
Permissible fluid tempera-
ture range
0 … 80 °C / 32 … 176 °F
Permissible ambient tem-
perature range
-20 to 40 °C / -4 to 104 °F
Permitted storage tempera-
ture range
0 … 50 °C / 32 … 122 F
Protection class
IP54
Empty weight
see type label
Filtration rating
ß(2) > 1000 (∆p 2.5 bar) for the
N5DMxxx or N10DMxxx filter el-
ement
Supply voltage/power con-
sumption
See the name plate on the elec-
tric motor
1
2
3
4
5
6
7
8
A