6.3.2 Circulation pumping without filtration
In operating mode Recirculation without filtration, replace the
filter element (900) with an empty element (910).
A suitable empty element (910) can be found in Chapter
Finding spare parts/accessories [
Fig. 24:
Empty element
Fig. 25:
Example of application: Recirculation
ü
Select the right filter element for an operating mode and
exchange this according to Chapter
1.
Connect the suction hose to the oil tank/container and fit
the suction hose in it and also secure it against falling
out.
2.
Connect the pressure hose to the oil tank/container and
fit the pressure hose in it and also secure it against
falling out.
3.
Connect the filter unit to the voltage source.
4.
Switch the filter unit on at the main switch.
5.
Continuously monitor the filling level in the tank/
container to be filled during recirculation.
6.
If the required filling quantity is reached, switch the filter
unit off at the main switch.