FAM 15/30/50/70
Troubleshooting
HYDAC Filter Systems GmbH
en
Page
58 /
68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc
2008-10-06
Overflow V-pump
Step
Description
1. Fault:
"V-pump overflow"
2.
Cause: fill level in the vacuum pump is too high
3.
Water Ring Vacuum Pump:
-
Water does not flow into the condensation tank
-
Check drain valve and clean if necessary
-
Check functioning of float switch
Rotary vane vacuum pump:
- Drain oil until the level is between Min. and Max.
4.
To reset the failure, press the RESET key
5.
The fault recurs?
->a. Yes
-> proceed to Step 7.
6.
->b. No
-> proceed to Step 8.
7.
Check SPS for proper
functioningThere may be too much
foam in the vacuum chamber ->
Reduce the vacuum
-> proceed to Step 4.
8.
The failure is repaired.