Preparing the Vacuum Pump
The rotary vane vacuum pump is not filled with oil at the time the FAM is delivered.
A sufficient amount of vacuum pump oil for the initial filling is included in the scope
of delivery.
NOTICE
Operation without vacuum pump oil
The rotary vane vacuum pump will be destroyed.
►
The rotary vane vacuum pump requires oil as its operating medium.
►
Check the oil level before star-up, topping up with vacuum pump oil VE101 if
necessary.
The maximum filling amount for vacuum pump oil VE101 is 0.3 liters.
The water level is monitored automatically by the integrated float switch while the
FAM is in operation. A message will appear on the control panel when the MIN MAX
filling level has been reached.
Synthetic vacuum pump oil in accordance with DIN 51506, Group VDL, ISO VG100
must be used for topping up.