Resolving errors/Eliminating errors
FAM 5
en-US
Page 103 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
32 Fill column
Trigger for the
message:
The "Min." switch point in the vacuum column was
reached/not met and not exceeded within 1.5 minutes.
Not enough oil has been pumped into the column. The
unit switches off immediately.
Remedy:
Perform the following steps:
S
te
p
Description
1.
Message:
32. Fill column
2.
Check all of the locking features in the supply line for flow /
freedom of passage. Open them if necessary. Make sure it is
below the oil level.
3
Acknowledge the error.
4.
Start the unit by pressing the F1 key.
5.
->a. The fault is repeated.
-> proceed to Step 6.
->b. The fault is not repeated.
-> proceed to Step 8.
6.
Clean the suction strainer.
Check the pump for proper functioning.
Check the function of the switch valve.
Clean the flow divider.
7.
->a. The fault is repeated.
-> proceed to Step 9.
->b. The fault is not repeated.
-> proceed to Step 8.
8.
The fault is repaired.
9.
Contact HYDAC Service.