ContaminationSensor CS 1000
Fastening / mounting the CS1000
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 19 / 108
BeWa CS1000 3247149p 240 en-us 2011-02-11.doc
2011-02-11
Fastening / mounting the CS1000
Install the CS in such a way that the flow runs from bottom to top.
Use the one (lower) port as the INLET and the other (upper) port as the OUTLET.
When selecting the installation site, take ambient factors like the temperature, dust,
water, etc. into account.
The CS1000 is designed for IP67 according to DIN 40050 / EN 60529 / IEC 529 /
VDE 0470.
Fasten the sensor in the following way:
1.
Wall mounting: using 2 cylindrical screws
featuring an M8 hexagonal socket, minimum
length: 40 mm, according to ISO4762.
2.
Console mounting: using 4 cylindrical screws
with an M6 hexagonal socket according to
ISO 4762.
A
B
100
60
12/16
4xM6
15
20
Bottom view
All dimensions in mm.