![HYDAC FILTER SYSTEMS OLFP-3 Series Installation And Maintenance Instructions Manual Download Page 49](http://html1.mh-extra.com/html/hydac-filter-systems/olfp-3-series/olfp-3-series_installation-and-maintenance-instructions-manual_2191464049.webp)
HYDAC FILTER SYSTEMS GMBH
Performing maintenance | 7
MoWa OLFP-3-6 3819798a en-us
49 / 76
13.
Insert the four bolts with washers for the filter cover in
the bore holes and screw on the nuts with washers be-
low by hand.
Tighten the four bolts
= 30 mm to a torque of 150
Nm.
To keep the bolts moving smoothly, we rec-
ommend coating the threaded connection with assembly
paste.
14.
(I)
Open the shut-off device slowly at the inlet
IN
to avoid
pressure shocks to the filter and fill the filter housing.
(II
) During the filling process, take note of the vent bore.
(III)
Shut the shut-off device at the inlet
IN
as soon as
fluid escapes.
15.
(I)
Screw in the vent screw clockwise using an Allen
wrench
= 10 mm.
Tighten the vent screw with a torque of 20 Nm.
(II)
Open the shut off device at the inlet
IN
.
(III)
Open the shut off device at the outlet
OUT
.
16.
After commissioning, check the filtration unit for leaks.
O
The replacement of the filter element is now complete.
The filter housing is ready for operation.