FAM 15/30 ATEX
Safety information and instructions
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 15 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Leaks of dangerous materials must be properly collected and disposed of so as not
to harm any persons or the environment. The corresponding statutory regulations
are to be followed.
Before any maintenance or repair work is carried out on the unit, electrical power to
the unit must be disconnected, and all hydraulic pressures relieved.
When work is done in explosion-prone areas, the safety of persons and
equipment depends on the observance of all relevant safety regulations. The
installation and maintenance personnel thus carries particular responsibility. Exact
knowledge of the applicable regulations and conditions is required.
Please note:
Observe the characteristic curves and measurement operating conditions of the
rating plates and data plates.
Damage to the devices can nullify the explosion protection.
The unit may be operated only when the control cabinet is completely closed.
Conversions and modifications to the devices and components that affect the
explosion protection are not allowed.
Proper/Designated Use
The FAM was designed for the dewatering, filtration and degassing of hydraulic and
lubricating oils. It removes free and emulsified water and most of the water which is
in solution.
Any other use shall be deemed to be improper and not in keeping with the product's
designated use.
Proper or designated use of the product extends to the following:
Maintaining adherence to all the instructions contained herein.
Performing requisite inspection and maintenance work.
Improper Use
Any use deviating from the proper/designated use described above is prohibited.
Improper use may result in hazard to life and limb.
Example of improper use:
Operation with non-approved fluids.
Operation in a danger zone where the ATEX classification of the device does not
apply.
Operation in mining or in dust-exposed zones