HYDAC FILTER SYSTEMS GMBH
Performing maintenance | 8
BeWa OF5F-OF5L 3160337i en-us
61 / 84
8.3 Cleaning the protective screen
To protect the pump from coarse contaminant particles or for-
eign bodies, a protective screen is installed in the suction
lance. Clean the strainer regularly. Check the protective screen
immediately in the event of insufficient suction or delivery rate.
NOTICE
Operation without the protective screen
The filter unit will be damaged/destroyed
u
Never operate the filter unit without a protective screen.
Item
Description
1
Suction hose
2
Suction lance
3
O-ring
4
Protective screen
5
Protection pipe
6
Protective screen set consisting of:
- Protective screen
- O-ring
- protection pipe
Tab. 6: Suction lance with protective screen
To clean the protective screen, proceed as follows:
ü
Switch the filter unit off at the main switch.
ü
Wear gloves.
ü
Remove the pressure and suction lances from the con-
tainers/reservoirs.
ü
Empty the suction hose into a suitable container, dirt
tank etc.
1.
Rotate the protection pipe (5) away from the suction
lance (2) in counterclockwise direction.
1
2
3
4
5
6
7
8
9
10
Summary of Contents for Filtromat OF5 F