Putting the FCU into operation [
7.2.2 Measuring oil up to max. 45 bar / 650 psi
For the measurement of permissible oil up to a maximum of
45 bar / 650 psi, proceed as follows:
WARNING
Hydraulic systems are under pressure
Danger of bodily injury
u
The system must be depressurized before performing any
work on the product.
u
If the pressurized connection is connected to the hydraulic
system, oil will flow through the FCU.
u
Make sure that the specified sequence is followed.
NOTICE
If the operating pressure exceeds 45 bar / 650 psi
The excess pressure will be discharged via port OUTLET
u
Never seal the connection OUTLET.
u
Put the free end of the OUTLET return hose into an un-
pressurized container.
u
When operating, always observe the permissible operating
pressure.
Required hoses:
-Return hose
-High-pressure hose