Connecting the FAM
FAM 15-70 ATEX
en
Page 33 /
88
BEWA FAM-15-70 II 2G IIB+H2 T4 EX02 4510066 en-us 2020-01-24.docx
2020-01-24
Connecting the (IN) suction port
NOTICE
Overpressure at the suction port connection
The unit will be damaged
►
The maximum permitted pressure Pe perm at the inlet to the FAM can
be found in the technical data.
NOTICE
Contamination too high
The unit will be damaged
►
Do not prime directly at the bottom of the tank.
►
Do not prime in the sump.
►
Never prime without a built-in suction screen.
NOTICE
Oil viscosity
The unit does not work without faults
►
Observe the defined viscosity range in the technical data
The greatest contamination is found on the bottom of the tank.
All impurities and other particles are deposited on the bottom of
the tank. All impurities and other particles are deposited on the
bottom of the tank.
Use a negative pressure-resistant, flexible hose or a pipe for the suction-side
connection.
Make sure that the cross-section of the connection lines is at least as large
as the cross-section of the connection threads.
The tank connection should be set up in such a way that it is always lower
than the level of the oil in the tank.