If the actual fluid level exceeds the upper limit of the unit's nominal
range, it can no longer be measured and the display starts to flash.
The values of the switching outputs and analogue outputs are
maintained. The measured peak fluid level or the pre-set offset is
shown in the display.
If, after a voltage breakdown, the display shows "..........." (flashing
centre LEDs), it should be checked whether the tank level is too high
or too low.
The analogue output provides 4 mA resp. 0 V depending on the setting
of the analogue input.
If the actual fluid level falls below the lower limit of the unit's nominal
range, it can no longer be measured and the display will start to flash.
The values of the switching outputs and analogue outputs are
maintained. In the display, 0.0 or the set offset appears.
8
Operating elements of the HNS 3000
The and arrow keys serve to select the desired menu item and to set the values.
One step back in menu
Choose menu item
Ascend in the menu
Reduce value
Confirm value
Increase value
9 Operation
modes
9.1 SIO
mode
After start-up, the pressure switch is in SIO mode (standard I/O mode). In this mode, Pin
4 serves as a switching output.
The centre LED is constantly lit.
According
Chapter
13
Basic Settings
the behaviour of the HNS 3000 can be adjusted to
the corresponding application.
HYDAC
mode
cm
°C °F
SP1
SP2
Display of
Temperature unit
4-digit
Digital display
LED display of
the active switch point
Operating buttons
LED display constantly lit: Switch in SIO mode LED
display flashing: Switch in SDCI mode
mode