HDA 4000W intrinsically safe, non-sparking, dustproof enclosure: ATEX and IECEx
11
Status: 2021-11-22
HYDAC ELECTRONIC GMBH
Part
no.: 670063
8
Technical Data
Input data
Measuring ranges
bar
25
40
60
100
160
250
400
600
1000 1600 2000
Overload pressures
bar
50
80
120
200
320
500
800
1000 1600 2400 3000
Burst pressure
bar
125
200
300
500
800
1250 2000 2000 3000 3000 4000
Measuring ranges
psi
300
500
1500
3000
5000
9000
10000 15000 20000 30000
Overload pressures
psi
1160
1160
2900
7250
11600 14500 14500 23200 34800 43500
Burst pressure
psi
2900
2900
7250
14500 29000 29000 29000 43500 43500 58000
Mechanical connection
see model code / dimensions
Tightening torque
see dimensions
Parts in contact with the fluid
Stainless steel
1
.4542; 1.4571; 1.4435; 1.4404; 1.4301; 1.4548
Seal
FKM (G1/4, SAE 6)
Output data
Output signal
Bluetooth Low Energy (see Bluetooth Interface Specification)
Accuracy acc. to DIN 16086,
terminal based
Typ.
Max.
0.25 % FS
0.5 % FS
Accuracy, B.F.S.L
Typ.
Max.
0.15 % FS
0.25 % FS
Temperature compensation
Typ
± 0.008 % FS / °C
± 0.015 % FS / °C
Offset
Max.
Temperature compensation
Typ.
± 0.008 % FS / °C
± 0.015 % FS / °C
Span
Max
Non-linearity acc. to DIN
16086, terminal based
Max.
0.3 % FS
Hysteresis
Max.
0.1 % FS
Repeatability
± 0.05 % FS
Sampling rate
10 ms .. 60 s adjustable via bluetooth
Long-term drift
Typ.
0.1 % FS / Year
Environmental conditions
Compensated temperature
range
-25 .. +85 °C
Operation / ambient / fluid
temperature range
1)
Ta = -30 .. +60 °C
Storage temperature range
-30 .. +60 °C
mark
EN 62368-1; EN 62479; ETSI EN 301 489-1/17; ETSI EN 300 328;
EN 60079-0/11
Bluetooth radio certification
FCC (USA)
IC (Canada)
CE (Europe)
Vibration resistance acc. to
DIN EN 60068-2-6
at 10 .. 500 Hz
5 g
Protection type acc. to
DIN EN 60529
IP 67
Relevant data for
Ex applications
Battery type required
2 x Energizer Ultimate Lithium AA L91
Other specifications
Service life
> 10 million load cycles 0 .. 100 % FS
Weight
approx. 150 g (without batteries)
approx. 300 g (including batteries)
Note:
FS
(
F
ull
S
cale) = relative to the full measuring range
B.F.S.L
. =
B
est
F
it
S
traight
L
ine
1)
-20 °C with FKM seal (G1/4, SAE 6)