2.3
GUIDE ARM DOWN
Pressing this key will move guide arm down.
GUIDE ARM UP
Pressing this key will move guide arm up.
CHIP CONV LEFT
Pressing this button will activate the chip conveyor and discharge the chips to the left side.
For the Right Infeed, after releasing the button, it will stay running for a predefined time.
CHIP CONV RIGHT
Pressing this button will activate the chip conveyor and discharge the chips to the right side.
For the Left Infeed, after releasing the button, it will stay running for a predefined time.
COOLANT ON
Pressing this key will start the coolant flow.
COOLANT OFF
Pressing this key will stop the coolant flow.
COOLANT AUTO
Pressing this key will cause the coolant to flow only when the blade is running OR when the
blade is running and the head is descending. This is selectable via the PLC parameters in
the SERVICE MODE.
FLOOD / MIST
Pressing this key will toggle between flood and mist cooling system
MANUAL MODE
Pressing this key will enable all of the “MANUAL MODE ONLY CONTROLS.”
AUTO MODE
Pressing this key will disable all of the “MANUAL MODE ONLY CONTROLS.” To enter
AUTO MODE, the FIXED VISE must be activated.
SERVICE MODE
The SERVICE MODE allows the user to adjust the various PLC parameters. The user will be
prompted for a password. Contact Hyd-Mech Group Limited to access this mode.
LASER ON / OFF
Pressing this key will cause the LASER to turn on or off. The red LED indicates that the
LASER will be on.
MACHINE START
Pressing this key will activate the control panel, display, and start the hydraulic system. The
EMERGENCY STOP button must be pulled out. This key must be activated to use the
machine functions.
MACHINE STOP
Pressing this key will shut down all machine functions including the control display and
hydraulic system. The display will not have a backlight on. All jobs will remain in memory as
will the QUEUE.
CYCLE START
The user will be prompted by the display to press this key as it is used to initiate an AUTO or
SINGLE CUT MODE cycle. Pressing this button will also initiate the QUEUE if pressed when
in the QUEUE screen.
CYCLE PAUSE
Pressing this key will pause the CYCLE in progress. If SHUTTLE is in motion and CYCLE
PAUSE is activated, the SHUTTLE will complete it’s movement and then the CYCLE will
PAUSE. To resume the CYCLE, press the CYCLE START key.
GUIDE ARM CONTROLS
COOLANT CONTROLS
MODE CONTROLS
MACHINE & CYCLE CONTROLS
CHIP CONVEYOR CONTROLS