Step 3 - Connect Tap to Tank
Fit the outlet flexible hose to the connection protruding from the base of the tap
using the supplied washer (white). Be careful not to strip or loosen the ends of the
copper pipe in the base of the tap.
Connect the other ends of the flexible hoses to the back of the heater using the pro-
vided washers.
The lead from the tap connects into the back of the unit just above the inlet and out-
let hoses.
Step 4 Connect to Water Supply
This product must be fitted with a relief valve. Figure 1 shows the recommended
installation. The pipe work to the relief valve should be made with 15mm copper pipe
with soldered joints. Once the installation has been completed as shown in figure 1,
the water can be turned on. Open the tap until water flows from the tap. Close the
tap and check the installation for leaks.
5. ELECTRICAL CONNECTION
REMINDER - DO NOT PROCEED UNLESS YOU ARE SURE THE TANK IS
FULL OF WATER. DAMAGE OR PERSONAL INJURY COULD OTHERWISE
RESULT.
Plug unit into 13A switched mains socket ensuring the supply chord does not come in
contact with the flexible hoses or pipe work.