3. Operation
This unit does not have an on/off switch and will operate as soon as mains power
is supplied to the unit.
4. Maintenance
•
Before
any maintenance or
cleaning, ensure the heater is disconnected from the
power supply and
has cooled completely.
•
Wipe the exterior of the heater with a damp cloth.
•
Do not use abrasives or chemical cleaners to clean the heater.
•
If the reflector requires cleaning, use a soft, dry cloth taking care not to touch the
quartz lamp with bare hands.
Lamp replacement
•
Check it is the correct lamp against the specification.
•
Do not touch the lamp with bare hands. Always use a soft cloth.
•
Do not touch the unit until it has been disconnected from the power supply and
has cooled completely.
•
Remove the four screws holding the lamp guard in place.
•
Remove the guard from the main body.
•
Remove the reflector.
•
Remove the back box covering the terminal block. Disconnect the lamp wires
from the terminal block that connects to the Live (L) and Neutral (N) terminals.
•
Remove the lamp from the reflector, pulling the wires carefully through and dispose
of safely.
•
Take the new lamp and feed the wires through the holes in the reflector.
•
Connect the lamp wires to the terminals marked L and N.