3. pLUMBInG connecTIonS

A service valve should be fitted to allow / facilitate future maintenance.

 

THe SUppLIed 6 BAR pReSSURe ReLIeF VALVe MUST ALWAyS Be  

 FITTed. THeRe MUST Be no oBSTRUcTIonS In THe  

 

pIpeWoRK BeTWeen THe HeATeR And THe ReLIeF VALVe.  

 

THe ReLIeF VALVe MUST dIScHARGe To A SAFe And VISIBLe  

 

pLAce.

The hot and cold fittings are ½” BSP and are at the top of the unit. These 
connections are colour coded (blue = cold, red = hot). They are not 
interchangeable.
The final connection of the Speedflow to pipework should be implemented with 
flexible stainless steel hoses.

 

open HoT WATeR TAp And ALLoW WATeR To RUn  

 THRoUGH FoR AT LeAST 5 SecondS To cLeAR AIRLocKS.

Depending on the installation circumstances, other accessories may be required. 
If required, these must be ordered separately and are installed as shown on the 
diagrams below and on the next page. Water pressure can increase considerably 
at night when demand is low, so a pressure reducing valve may be required even if 
there is no obvious problem at installation.

DIAGRAM A - pressure below 4.2 bar

no accessories needed

Summary of Contents for SF10K

Page 1: ...Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2 0 May 2009...

Page 2: ...P USE LOWEST ACCEPTABLE TEMPERATURE SETTING TO SAVE ENERGY AND REDUCE LIMESCALE DO NOT CONNECT TO POWER UNLESS UNIT IS FULL OF WATER OPEN TAP AND ALLOW WATER TO FLOW FREELY TO CLEAR AIRLOCKS DO NOT SW...

Page 3: ...t interchangeable The final connection of the Speedflow to pipework should be implemented with flexible stainless steel hoses Open hot water tap and allow water to run through for at least 5 seconds t...

Page 4: ...arthed IMPORTANT DO NOT SWITCH THE HEATER ON UNLESSYOU ARE CERTAIN THAT IT IS COMPLETELY FULL OF WATER FAILURE TO DO SO WILLVOID THE WARRANTY DIAGRAM B Cold draw off nearby DIAGRAM C Pressure above 4...

Page 5: ...heating The thermal cut out may trip occasionally in normal use If this happens the heater will not heat water and the element light will not come on The thermal cut out is located underneath the uni...

Page 6: ...artment on 01977 517555 To access the element or anode unscrew the bolts holding the flange in position The element and anode can then be removed Reverse to re fit 7 MAINTENANCE A grey cylindrical mag...

Page 7: ...Replace element See section 6 for access to element 3 Thermostat has failed 3 Replace thermostat Small volume of hot water 1 Unit upside down 1 Re install correct way up 2 Thermostat set too low 2 In...

Page 8: ...ND SERVICE POLICY This product is guaranteed against fault materials and manufacture for a period of one year from the date of purchase Hyco will in its sole discretion replace repair or refund any fa...

Reviews: