3. Operation
Once installed and connected to the electrical supply the heater is ready for use.
Turn on the heater using the power On/Off button. On first installation the
temperature setting will default to 38
0
C. To adjust this press the +/- buttons until
the desired maximum target temperature is displayed. The heater will automatically
begin heating when it detects a flow of water through it (min 2.0L/m).
Open the outlet valve and check the display, the temperature display will flash if the
set temperature cannot be reached. It may be possible to reduce the flow rate in
order to achieve the set temperature, but it must have a minimum flow of 2.0L/min
in order to operate.
Due to the nature of instantaneous heaters, water is only heated as it passes
through the tank. Because the maximum power of the heater is fixed there is
a limit to the rate at which hot water can be delivered.
The heater incorporates intelligent control and will ensure the maximum
temperature setting is not exceeded regardless of drop in flow or increase in
incoming water temperature.