background image

Children shall not play with the appliance. Cleaning and user maintenance shall 
not be made by children without supervision.

Only use the supplied fittings when installing the heater, do not attempt to 
modify them in any way.

Statement of Conformity

Hyco Manufacturing Ltd. duly declares that the Handyflow range of water heaters comply with the 

following directives: 

•  

Low Voltage Directive 2006/95/EC 

•  

Electromagnetic Compatibility Directive (EMC) 2004/108/EC

•  

CE Directive 93/68/EC

The product also conforms to the following harmonised European standards: 

•  

E 62233:2008 

•  

EN 60335-1:2012 

•  

EN 60335-2-21:2003 AI:2005

Hyco Manufacturing Ltd. Castleford, West Yorkshire, WF10 5NR. 30-04-2014

2. Mounting Instructions

Environment

This heater is delivered in sturdy packaging in order to avoid damage during 
transport. This packaging consists mainly of recyclable materials. We request 
that you dispose of the packag- ing accordingly for recycling.

Frost

All steps should be taken to avoid the risk of frost damage to the heater. 
If the heater is likely to be exposed to a risk of frost, all efforts should be made 
to prevent this, such as the lagging of pipe work.

4

HF05LM _Layout 1  18/05/2015  10:54  Page 4

Summary of Contents for HF05LM

Page 1: ...Product Instruction Manual Handyflow Oversink HF05LM 5L vented point of use water heater Version 3 2 Jan 2015 v15 4...

Page 2: ...2...

Page 3: ...uld be installed by qualified persons All repair and maintenance work on the heater for example the removal of limestone and water scale deposits may only be carried out by duly authorised technical s...

Page 4: ...8 EC The product also conforms to the following harmonised European standards E 62233 2008 EN 60335 1 2012 EN 60335 2 21 2003 AI 2005 Hyco Manufacturing Ltd Castleford West Yorkshire WF10 5NR 30 04 20...

Page 5: ...e positioned before attaching the bracket Plumbing Connect the inlet valve to the cold pipe indicated by the blue collar and make the plumbing connection via the 15mm compression fitting supplied Conn...

Page 6: ...he manufacturer or an au thorised agent or by an equivalently qualified person Ensure that the addition of this heater will not overload the fuse protection in your electrical supply Internal modifica...

Page 7: ...water volume litres minute 5 Nominal capacity kW 2 Nominal voltage V 1 N PE 230V Frequency Hz 50 Protection class I I IP rating IP24 Water connection inches G1 2 Connector material Brass Dimensions h...

Page 8: ...shooting for further details Temperature setting Cold heater is switched off Frost protection the device switches on if the water temperature falls below 7 C Heats water to approx 32 C Economy positio...

Page 9: ...ot require any maintenance by the user Professional maintenance should always be carried out by an expert If faulty never try to repair the heater yourself Please contact the nearest service specialis...

Page 10: ...Tap drips Water expansion Nothing this is normal for vented water heaters Bubbling noise from Too much calcification Arrange for the heater to be the tank de scaled Heater not working If the heater n...

Page 11: ...of one year from the date of purchase Hyco will in its sole discretion replace repair or refund any faulty unit Incorrect installation frost damage and the consequences of limescale deposits are exclu...

Page 12: ...to a dealer providing this service Disposing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resource...

Reviews: