6
5. Maintenance
Always isolate the appliance from the power supply prior to any
maintenance or adjustment.
•
Remove any dust or debris form the inlet holes.
•
Wipe the exterior with a soft damp cloth.
•
Do no use abrasive chemicals on the dryer.
It is possible to adjust the sensing distance of the hand dryer if required. First remove
the cover and then locate the variable resistor (bottom left hand corner of the dryer).
To adjust the sensor range, use a small flat head screwdriver and turn clockwise to
increase or anti clockwise to reduce.
Sensing distance
adjustment