Model identifier(s):  AVG1500T 
Item 

Symbol 

Value 

Unit 

Item 

Unit 

Heat output 

Type of heat input, for electric storage local 
space heaters (select one) 

Nominal heat output 

Pnom 

1.5 

kW 

manual heat charge control with 
integrated thermostat 

No 

Minimal heat output 
(indicative) 

Pmin 

1.5 

kW 

manual heat charge control with 
room and/or outdoor 
temperature feedback   

No 

Maximum continuous 
heat output 

Pmax, 

1.5 

kW 

electronic heat charge control 
with room and/or outdoor 
temperature feedback 

No 

Auxiliary electricity consumption 

fan assisted heat output 

No 

At nominal heat 

output 

elmax 

kW 

Type of heat output/room temperature 

control (select one) 

At minimum heat 
output 

elmin 

kW 

single stage heat output and no 
room temperature control 

No 

In standby mode 

elSB 

0.0

0

1  kW 

two or more manual stages, no 
room temperature control 

No 

with mechanic thermostat room 
temperature control 

Yes 

with electronic thermostat room 
temperature control 

No 

electronic room temperature 
control plus day timer 

No 

electronic room temperature 
control plus week timer 

Yes 

Other control options (multiple selections 
possible) 
room temperature control, with 
presence detection 

No 

room temperature control, with 
open window detection 

Yes 

with distance control option 

No 

with adaptive start control 

No 

with working time limitation 

No 

with black bulb sensor 

No 

Contact details: Hyco Manufacturing Ltd, Castleford WF10 5NR

www.hyco.co.uk

 

1

4

Summary of Contents for AVG1500T

Page 1: ...Product Instruction Manual Avignon AVG600T AVG900T AVG1500T AVG1800T Aluminium radiator Version 3 2 Jan 2015 V18 3 2...

Page 2: ...king the radiator 3 5 Setting the time and date 3 6 Free operating mode 3 7 Timer Mode 3 8 Programming your radiator 3 9 Program mode 3 10 Default temperature settings 3 11 Daily settings P1 P9 3 12 F...

Page 3: ...ring Regulations Only connect the unit to a single phase supply with a mains voltage as specified on the rating plate The supply cord cannot be replaced by the user If the cord is damaged the applianc...

Page 4: ...d and do not modify the bracket In order to avoid overheating do not cover the heater Fixed heaters likely to be used in bathrooms are to be installed so that switches and other controls cannot be tou...

Page 5: ...lugs and fasten the bracket onto the wall using the screws provided Fig 3 Ensure that the plastic mounting brackets are fitted to the back of the radiator as shown Offer up the radiator to the bottom...

Page 6: ...age as specified on the rating plate If the heater is to be connected to the fixed wiring of the property then installation must include a double pole isolating switch with a break contact distance of...

Page 7: ...he appliance where the power cable enters the radiator 3 Briefly press the on off button until the on off icon on the display panel disappears you are now in Free Operating Mode 3 4 Unlocking the radi...

Page 8: ...clock appears use the up and down arrows to select the amount of time you would like the radiator to stay on for After the display has stopped flashing a clock icon will appear 3 The radiator will swi...

Page 9: ...our The pre set programs are provided to make things easier for you However these programs are 100 customisable 3 12 Fine tuning P1 P9 1 Select the program you wish to alter as above in Entering Progr...

Page 10: ...the radiators ON button The symbol FO disappears from the display Activating the Open Window Function 1 Press P Prog once Using the up and down arrows select FO from the list of abbreviations and pre...

Page 11: ...oft dry cloth Never use chemical or abrasive cleaners Clean the radiator at least once a year with a vacuum cleaner to remove any accumulated dust 5 Specifications Model AVG600T AVG900T AVG1500T AVG18...

Page 12: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Page 13: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Page 14: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Page 15: ...room temperature control select one At minimum heat output elmin 0 kW single stage heat output and no room temperature control No In standby mode elSB 0 001 kW two or more manual stages no room temper...

Page 16: ...onic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of this equipment separate...

Reviews: