Item                                                                                                                                                        Unit

Type of heat input, for electric storage local space heaters (select one)

manual heat charge control with integrated thermostat                                             No

manual heat charge control with room and/or outdoor                                              No
temperature feedback                                                                                                              

electronic heat charge control with room and/or outdoor                                          No
temperature feedback                                                                                                              

fan assisted heat output                                                                                                           No

Type of heat output/room temperature control (select one)

single stage heat output and no room temperature control                                      No

two or more manual stages, no room temperature control                                        No

with mechanic thermostat room temperature control                                                 No

with electronic thermostat room temperature control                                                 No

electronic room temperature control plus day timer                                                     No

electronic room temperature control plus week timer                                                 Yes

Other control options (multiple selections possible)

room temperature control, with presence detection                                                        No

room temperature control, with open window detection                                               Yes

with distance control option                                                                                                      No

with adaptive start control                                                                                                          No

with working time limitation                                                                                                      No

with black bulb sensor                                                                                                                 No

13

Summary of Contents for AC1000T

Page 1: ...Product Instruction Manual Accona AC500T AC1000T AC1500T AC2000T Panel heater Version 3 2 Jan 2015 V18 4 1...

Page 2: ...ints The electrical installation must be carried out by a qualified electrician in accordance with the current edition of the I E E Wiring Regulations Only connect the unit to a single phase supply wi...

Page 3: ...r installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children age...

Page 4: ...t away from the heater Ensuring a horizontal level offer the bracket to the wall and mark the four holes located at each corner of the bracket Drill the four holes in the mounting surface and insert t...

Page 5: ...arried out by a qualified electrician in accordance with the current edition of the I E E Wiring Regulations Connection should be made to the fixed wiring of the property via a double pole fused spur...

Page 6: ...hen need to press the standby on off button under the LED indicator to activate the panel Setting the clock Hold down the SET OK buttons simultaneously until a beep sounds and the current day setting...

Page 7: ...target temperature display will be replaced by icon to indicate the panel is locked Repeat the first step to unlock the heater Manual operation The most basic setting of the heater allows the user to...

Page 8: ...f the heater is switched off or placed into standby mode Automatic operation 24 7 timer Example below shows a timer programmed for TUESDAY to switch ON at 8 00am 08 and OFF at 5 00pm 17 This is schedu...

Page 9: ...rea 3 on the annotated image and the previous steps for setting the switch on and off hours should be followed Up to 4 individual start stop times can be specified for each day but it is possible to e...

Page 10: ...it and the outlet louvres at the front of the heater Ensure they are cleared of dust or other debris that may causes a blockage and in turn reduce the airflow in and out of the heater which if uncheck...

Page 11: ...ly 230V AC 50Hz Power half full 250 500W 500 1000W 750 1500W 1000 2000W Water resistance IP24 Class I Weight 3 4kg 3 4kg 4 7kg 5 2kg Thermal protection Auto reset thermostat x 2 Size w x d x h 460x90x...

Page 12: ...0T A2000T Heat output Nominal heat output Pnom 0 5 1 0 1 5 2 0 kW Minimal heat output Pmin 0 25 0 5 0 75 1 0 kW indicative Maximum continuous Pmax c 0 5 1 0 1 5 2 0 kW heat output Auxiliary electricit...

Page 13: ...tput and no room temperature control No two or more manual stages no room temperature control No with mechanic thermostat room temperature control No with electronic thermostat room temperature contro...

Page 14: ...ning E1 Temperature sensor error E3 Overheat event In the case of an E3 Overheat event the heater will beep until any button is pressed to clear the fault The cause of the overheat should be investiga...

Page 15: ...etion supply a replacement product Incorrect installation and failure to follow correct operating instructions are excluded Consequential costs such as labour charges or damage to surroundings are exp...

Page 16: ...king life this equipment must not be disposed of as household waste It must be taken to a local authority waste collection centre or to a dealer providing this service Disposing of electrical and elec...