4
Connection.to.central.heating.system.
HWAM.Elements.can.be.connected.to.a.new.or.an.existing.central.heating.system.as.a.sup-
plementary.auxiliary.kettle ..The.water.supply.must.be.connected.at.4,.and.the.return.water.from.
the.woodburning.stove.must.be.connected.the.return.line.of.the.system ..A.part.of.the.water.
supply.will.then.circulate.through.the.stove.where.it.is.heated.further,.before.it.is.mixed.with.the.
colder.return.water .
At.the.same.time.it.is.secured.that.there.is.always.flow.in.the.stove,.no.matter.if.the.radiator.
thermostats.of.the.heating.system.should.be.closed .
Depending.on.the.need.for.heat,.the.shunt.valve.can.be.set.at.‘summer.position’.for.quickly.
utilization.of.the.stove.to.heat.other.rooms.with.radiators ..If.the.need.for.heat.is.not.very.impor-
tant.it.might.be.necessary.to.set.the.shunt.towards.‘winter.position’.to.involve.more.water.in.the.
circulation ..With.the.shunt.in.‘winter.position’.the.kettle.heats.domestic.water .
HWAM Elements connected to a central heating system
.. Automatic.aeration
.. Thermal.drain.security
.. Outlet
4 .. Supply.by.AVTA.valve
5 .. Floor.heating
6 .. Radiator
7 .. Supply
8 .. Return
9 .. Return.conduit.and.relief.pipe
0 .. Oil-fired.burner
.. Hot.water
.. Closed.expansion.tank
.. Shunt.valve
4 .. Pump