24
I
nstallatIon
General information
Installation of your HWAM woodburning stove must always comply with local building regulations. It is
a good idea to consult your local chimney sweep before installing, since he will be the one to sweep the
chimney and stove.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be installed. A window
that opens or an adjustable air vent should be sufficient. The air inlet/grating must be placed so that they
do not become blocked.
Load-bearing capacity of floor
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand
the weight of the stove and the chimney. The weight of the chimney should be calculated according to
its dimensions and height.
Technical data
Model
Weight
Height
Width
Dept
HWAM Classic 7H
184 kg
120,0 cm
64,0 cm
50,2 cm
Test results from nominal test EN 13240
Nominal heating effect
11 kW
Smoke temperature
227 ºC
Exhaust gas flow
13.20 g/s
Efficiency
79.3 %
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is installed
on a wooden floor or similar, the floor must be covered with a non-combustible material.
HWAM Classic 7H (Drawing A)
1.
Recommended for brick wall
10 cm
1.
For inflammable back wall
10 cm
2.
For inflammable side wall
25 cm
1.
To inflammable wall,corner installation
15 cm*
3.
Distance to furnishings in front
80 cm
*All distances in connection with corner installation are only recommendations. Contact your chimney
sweep for a clarification.
Remember to pay attention to any regulations concerning the required distance between
the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the Autopilot system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The chimney must be of a sufficient height to enable an adequate draft and to prevent smoke problems.
The stove requires a draft of at least 12 Pa.