The instrument can display the current value and display the current
frequency and other data;

-type and Y-type connection capacitors can also be measured besides

the group of capacitors;

320×240 large-screen liquid crystal display and Chinese menu prompts
makes it easy to operate;

Built-in large-capacity non-volatile memory: Each test option can store

256 sets of data;

Built-in USB controller interface can export instrument memory data,which
makes it easy for report generation;

Built-in high-precision real-time clock function for date and time calibration;

The instrument comes with a high-speed micro thermal printer to print
measurement and historical data;

Function of test power supply over-current protection can ensure the
instrument will not be damaged when the power supply outputs short
circuit.

III Technical Parameters

Measurement range
Capacitance

2uF

2000uF

Inductance

5mH

5000mH

Current

20mA

2000mA

Measurement accuracy
Capacitance

:±

(1% r 2 words)

Inductance

:±

(1% r 5 words)

Current

:±

(1% r 2 words)

Dimensions

345mm

×

295mm

×

175mm

Instrument weight

7kg

Summary of Contents for HTRG-H

Page 1: ...nual You can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column ma...

Page 2: ...and prevent the product or other relevant subassembly to damage In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out main...

Page 3: ...d the instruction manual to acquire information about the ratings Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type an...

Page 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Page 5: ...5 Contents I Product Overview 6 II Function Features 6 III Technical Parameters 7 IV Working condition 8 V Panel Introduction 8 VI Operation Introduction 9 VII Attentions 16 VIII Packing list 17...

Page 6: ...rs The newly developed capacitor and inductance tester of our company can measure a single capacitor of a group of parallel capacitors without disconnecting the wire and can also measure the inductanc...

Page 7: ...ta which makes it easy for report generation Built in high precision real time clock function for date and time calibration The instrument comes with a high speed micro thermal printer to print measur...

Page 8: ...ltage output test terminal 2 Current input signal input socket for clamp current transformer 3 Power switch power switch and insurance of the instrument 4 Grounding column dedicated to the safety grou...

Page 9: ...ion or software upgrade between the instrument and the PC 9 USB interface linked with large capacity external mobile storage devices VI Operation Introduction 6 1 Wiring Direction 6 1 1 Typical test w...

Page 10: ...display the main menu which is shown in the following figure 6 2 1 Capacitance Test In the interface of Main Menu press the key SEL or key and select the option of Test then press OK to enter the Test...

Page 11: ...hase connections can be selected when the capacitance is tested Note This setting is invalid when measuring inductance or current Vol Level refers to the nominal voltage level of the test object used...

Page 12: ...in the right top figure Press the button Stop to cut off the output of the test power and the test is over In the Testing Capacitance interface the current test results can be saved in local memory by...

Page 13: ...he key Save and the current test parameters and test results can be printed by pressing the key print In the Testing Inductance interface press the key Back to cut off the output of the test power and...

Page 14: ...key Back to cut off the output of the test power and return to the Test Options interface 6 2 4 Record In the Main Menu interface press the key SEL or to select the Record and then press the key OK t...

Page 15: ...same time to format and delete all the history records Please operate with caution 6 2 5 Time SET In the Main Menu interface press the key SEL or to select Time SET and then press the key OK to enter...

Page 16: ...o it should be taken good care of during the process 7 3 If the over voltage and over current protection act identify the reasons and exclude the abnormal situation before continuing to test do not bl...

Page 17: ...Test leads red black with clip 5M 1 3 220V AC power cord 1 4 Clamp Current Sensor 1 5 USB communication wire 1 6 Short circuit wire with clip 2m 1 7 Ground wire 1 8 5A fuse 6 9 U disk 1 10 Instruction...

Reviews: