background image

10

the insulation resistance among components of electronic products,

the “L” terminal and the “E” terminal can be connected to any line.

When measuring the resistance between phases of electrical

generator, you can choose two among the three phases at will, and

the remaining one should be grounded.

V. Notes

1. When the meter is stored you should pay attention to

environment temperature and moisture. The meter should be place

in dry and ventilated environment and should be shielded from dust,

humidity, vibration, acid, soda and corrosive gas damage.

2. When the measured object is charged, you should disconnect

the power before starting the measurement. Otherwise, that may

endanger safety of your body and the device! The DC voltage

between the “E” terminal and “L” terminal is high after turning on the

high voltage. Make sure any parts of your body should not touch the

terminals during measuring.

3. This meter uses AC and DC power supply. When connect to

AC power supply, the meter will prior use AC power supply; when

not connect to AC power supply, battery will power meter.

4. “←” appearing on the top left corner of the screen says

battery voltage is low and you should replace a new battery. If the

meter will not be used for a long time, all batteries should be

Summary of Contents for HT2671

Page 1: ...ou can find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column may brin...

Page 2: ...r relevant subassembly to damage In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out maintenance or repair work To avoid...

Page 3: ...uire information about the ratings Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type and rating specified for the prod...

Page 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Page 5: ...5 Contents I Introduction 6 II Function and Features 7 III Technique Specification 8 IV Operation Instructions 9 V Notes 10...

Page 6: ...e to L pole via the object being tested By this way it produces a current from pole E to pole L which converted by I V and computed by the divider The value of insulation resistance will display on th...

Page 7: ...rder active low pass filter it can play an effective role in shielding external power frequency and strong electromagnetic field For the measurement of capacitive specimen since the short circuit curr...

Page 8: ...0 01M 0 1M 1 0M 10 0M Relative error 0 2000M 5 2d 2000M 19990M 10 2d 3 Load ability of maximum output voltage and short circuit current Voltage Load 2500V 20M Voltage drop Approximately 10 Short circ...

Page 9: ...left most position Pressing start stop button will turn off the high voltage Pressing down the ON OFF button will turn off the power supply Notes As measure accompanied with absorption and polarizati...

Page 10: ...orrosive gas damage 2 When the measured object is charged you should disconnect the power before starting the measurement Otherwise that may endanger safety of your body and the device The DC voltage...

Page 11: ...11 removed to prevent meters from corrosion...

Reviews: