background image

24

should be regularly charged, so as not to damage the battery.

X. Packing list

XI.Common fault repair

Fault phenomenon

Reason

Solution

Power on, power

indicator light does not

shine

1.indicator broken

2.battery out power

3. The circuit board in the

host is faulty

1. See if there is an image

on the screen

2.Charge

3. Contact the supplier.

Power on, power

indicator light, but no

image

1. Contrast adjustment

improperly

2. The circuit board in the

host is faulty

1.Adjust contrast knob

2. Contact the supplier.

Boot, there are

images, but no

emission waveform

1. Contrast adjustment

improperly

2. The circuit board in the

host is faulty

1. Adjust contrast knob,

press impulse.

2. Contact the supplier.

When measuring,

there are emission

waveforms, no

reflection waveform

1. Measuring range is

wrong

2. The output test leads

are not connected well to

the cable under test

3. The circuit board in the

host is faulty

1. Adjust measurement

range

2.Check wiring

3. Contact the supplier.

1. Host

1

2. Power cord

1

3. Output cable

1

4. Instruction manual

1

5. Inspection report

1

6. Certificate

1

Summary of Contents for HT-TC

Page 1: ...n find the changes in the appendix Sorry for the inconvenience If you have further questions welcome to contact with our service department The input output terminals and the test column may bring vol...

Page 2: ...r relevant subassembly to damage In order to avoid possible danger this product can only be used within the prescribed scope Only qualified technician can carry out maintenance or repair work To avoid...

Page 3: ...uire information about the ratings Do Not Operate without Covers Do not operate this product when covers or panels removed Use Proper Fuse Only use the fuse with type and rating specified for the prod...

Page 4: ...Security Terms Warning indicates that death or severe personal injury may result if proper precautions are not taken Caution indicates that property damage may result if proper precautions are not tak...

Page 5: ...ng Method 9 IV High Voltage DC Flashover Method 11 V High Voltage Impulse Flashover Method 12 VI Fundamantal Principle and Composition 13 VII Panel Controlling and Keymanual s Function 15 VIII Instrum...

Page 6: ...ed electronic devices and with computer and special electronic technology combining our company s successful experience of long time exploitation on cable fault measuring testing instruments and it is...

Page 7: ...gh speed data sampling the speed of A D is 100MHz and makes resolution ratio of 1m and testing dead zone of 1m 1 3 High intelligent The testing results automatically show by wave form and data on the...

Page 8: ...e parameters 2 1 Scope of application and using purpose The instrument can test all kinds of electric cable voltage of 1KV 35KV and the Short Circuit Grounding Leakage of High Resistance High Resistan...

Page 9: ...t but not the length of the line In the symmetrical transportation line the resistance input equals the unique resistance at any point If the load of terminal equals the unique resistance the current...

Page 10: ...below V is the speed of the electric wave of the line and is related to the linear circuit parameter and constant to an case which can be detected by the instrument and calculated by computer When the...

Page 11: ...point is first been sparked over forming the flashover and we can use the electric arch added to the voltage to form a short circuit reverse The reverse wave at the input terminal forms the open reve...

Page 12: ...er electirc arch At the input terminal of cable we detect the inductance L to read the reverse wave The circuit principle graph is as below Electric wave reverse at the fault point and reverse by L at...

Page 13: ...capture and displaying the einmal transient wave The instrument applies the technology of digital storing using the high speed A D converter to get sample and converts the transient analog signal to...

Page 14: ...done by microprocessor concludes data sampling data storing data filtration cursor moving distance computing graph comparing graph size changing and displaying on the LED And it also can depend on nee...

Page 15: ...Panel Controlling and Keymanual s Function 1 On off control the power of the device on or off Press the button the device has the power and displayer will show the window of operations 2 Mode press i...

Page 16: ...he display scale by pressing the decrease increase key VIII Instrument use fault test method 1 Fault type detect Before the test cable fault first determine the type of fault in order to determine whi...

Page 17: ...e impulse button to send the test pulse the screen to get reflected waves 7 Press the button to move the cursor to the start of the reflected wave If the reflected wave is not well discriminated adjus...

Page 18: ...the gain and retransmit the pulse make the front of the most steep reflection wave I Press or to move the measuring cursor to the leading edge of the reflected wave and the upper left corner of the s...

Page 19: ...ectric cable Preventative spark over testing usually applies this method C The time of the high voltage current flashover method varies and the short one can exist for some times The wave form is simp...

Page 20: ...ises heavily and the indicator in voltage meter also alters heavily The wave form as below should be on the screen From the graph the interval of t1and t2 should be the distance of the fault points F...

Page 21: ...d the high voltage testing equipment whether has a good water resistance and voltage divider C Connect the devices as below The ground line works as 8 2 6 and 9 3 The capacity in it is demanded higher...

Page 22: ...Waveform comparison method A Disconnect all equipment from the cable under test B Connect the normal cable to the output port of the tester C Use the low voltage pulse method to read the measurement w...

Page 23: ...and assuage the process of discharging After the voltage of capacitor is low it can discharge directly to the ground until the voltage is zero If discharging in seconds the instant current can reach...

Page 24: ...ard in the host is faulty 1 Adjust contrast knob 2 Contact the supplier Boot there are images but no emission waveform 1 Contrast adjustment improperly 2 The circuit board in the host is faulty 1 Adju...

Page 25: ...able HEQ212 4 12 Gap of cables 240m s other 248m s Oil immersed communicating insulating cable in lead ZUQ 6KV3 703 150 Core core 160m s PVC insulating cable VLZ 3 120 1 35 1KV3 50 1 16 Core core 178m...